NameDescription
o3 Temp coef 1 Temperature coefficient normalized to zero for slit #1
o3 Temp coef 2 Temperature coefficient for slit #2 relative to slit #1 (Slit #2 TC - Slit #1 TC)
o3 Temp coef 3 Temperature coefficient for slit #3 relative to slit #1 (Slit #3 TC - Slit #1 TC)
o3 Temp coef 4 Temperature coefficient for slit #4 relative to slit #1 (Slit #4 TC - Slit #1 TC)
o3 Temp coef 5 Temperature coefficient for slit #5 relative to slit #1 (Slit #5 TC - Slit #1 TC)
Micrometer steps/deg
O3 on O3 Ratio Absorption value for Ozone
SO2 on SO2 Ratio Absorption value for Sulfur dioxide
O3 on SO2 Ratio Absorption value for Ozone on the Sulfur dioxide
ETC on O3 Ratio The Extraterrestrial Constant (ETC) used for calculating Ozone
ETC on SO2 Ratio The Extraterrestrial Constant (ETC) used for calculating Sulfur dioxide
Dead time (sec) Dead time the instrument is set to
WL cal step number Current cal step for the instrument
Slitmask Motor DelayMulti-board electronics - This is the slitmask delay between moving from one slit to the next. The typical value for this is 80
New Electronics - This sets the speed of the slitmask motor, typically and usually left at 14.
Umkehr Offset Azimuth offset during Umkehr measurements
ND filter 0 Filer correction from Neutral Density (ND) filter #0
ND filter 1 Filer correction from Neutral Density (ND) filter #1
ND filter 2 Filer correction from Neutral Density (ND) filter #2
ND filter 3 Filer correction from Neutral Density (ND) filter #3
ND filter 4 Filer correction from Neutral Density (ND) filter #4
ND filter 5 Filer correction from Neutral Density (ND) filter #5
Zenith steps/rev The number of steps to perform a complete rotation of the zenith
Brewer Type Version of Brewer spectrophotometer
COM Port # Select the comport being used. **if using dosbox or similar dos emulator, this is not the actual comport used on the computer, but the comport specified in the config. Typically left as 1
o3 Temp coef hg
n2 Temp coef hg
n2 Temp coef 1
n2 Temp coef 2
n2 Temp coef 3
n2 Temp coef 4
n2 Temp coef 5
O3 Mic #1 Offset The number of steps from the bulkhead LED to the micrometer 1 HG test position
Mic #2 Offset The number of steps from the bulkhead HED to the micrometer 2 HP test position
O3 FW #3 Offset Offset from the filter wheel #3 zero position during Ozone measurements
NO2 absn Coeff Absorption value for Nitrogen dioxide
NO2 ds etc Direct sun (DS) Extraterrestrial Constant for Nitrogen dioxide measurements
NO2 zs etc Zenith sky (ZS) Extraterrestrial Constant for Nitrogen dioxide measurements
NO2 Mic #1 Offset Micrometer #1 position in steps for Nitrogen dioxide measurements
NO2 FW #3 Offset Filter wheel #3 position in steps for Nitrogen dioxide measurements
NO2/O3 Mode Change
Grating Slope The relationship of movement between micrometer #1 and micrometer #2 to maximize counts
Grating Intercept
Micrometer Zero
Iris Open Steps The number of steps it takes to open the Iris
Buffer Delay (s)
NO2 FW#1 Pos Position of filter wheel #1 during a Nitrogen dioxide measurement
O3 FW#1 Pos Position of filter wheel #1 during Ozone measurements
SL FW#2 Pos Position of filter wheel #2 during any tests or measurements that use the standard lamp
uv FW#2 Pos Position of filter wheel #2 during a UV measurment
Zenith Offset Offset from the zenith zero positioning for optimal pointing
Zenith UV Pos Zenith position in steps when performing a UV measurement
Release date Date that the ICF was created
EXTRAS
AUTO HGAllows the software to automatically insert HG as required when running a schedule with auto routine. Typically an HG is ran every 2 hours or a change in temperature of 2 degrees, which ever happens first.
0 - Disable
1 - Enable
FW2 oscilAllows filterwheel 2 to keep changing with no limits during DS measurements. This usually happens when the sun gets covered/uncovered by moving clouds.
HG FW#2 Pos Position of filter wheel #2 when using the Hg bulb
Low Signal limit The number of counts at which the instrument will switch to a lower neutral density filter or skip the test during a direct sun measurement
Upper Signal limit The number of counts at which the instrument will increase the neutral density filter during a direct sun measurement
Use cubic DSPEnable the use of cubic dispersion.
0 - Disable
1 - Enable
Skip DS if too dim Enable skipping a Direct Sun (DS) measurement if counts are too low
O3ETC-R6 Ozone Extraterrestrial Constant (ETC) minus the R6 standard lamp ratio
So2ETC-R5 Sulfur dioxide Extraterrestrial Constant (ETC) minus the R5 standard lamp ratio
PHYCS alpha / slits 2-5 / o3 PHYCS correction factor for stray light on slits 2 - 5
PHYCS beta / slit 1 / so2 PHYCS correction factor for stray light on slit 1
Apply PHYCS If PHYCS is in use (1=Y, 0=N)
Updated with CF