User Tools

Site Tools


mm

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
mm [2025/08/11 18:23] renomm [2025/08/12 13:54] (current) reno
Line 30: Line 30:
   s refer to the number of steps to move   s refer to the number of steps to move
 |M,10,500|Moves motor m to step s. Note: when moving backwards (negative number) it will set that as the new reference point. [[motor|Click here more motor information]].| |M,10,500|Moves motor m to step s. Note: when moving backwards (negative number) it will set that as the new reference point. [[motor|Click here more motor information]].|
-|N,s|s refers to the number of steps|N,500|(Used for [[singleboard|singleboard electronics]] only.) Moves both micrometer 1 and 2 to step s. Note: when moving backwards (negative number) it will set that as the new reference point. [[motor|Click here more motor information]].| 
 |O| |O|This command outputs the number of counts returned in a measurement. |O| |O|This command outputs the number of counts returned in a measurement.
 |R,p1,p2,t|\\ |R,p1,p2,t|\\
Line 75: Line 74:
 |BOP2MAX|This command will move the micrometer 2 to max/op/min position to max/op/min. It assumes the micrometer is already in the start location. This is use to help test the micrometer range.| |BOP2MAX|This command will move the micrometer 2 to max/op/min position to max/op/min. It assumes the micrometer is already in the start location. This is use to help test the micrometer range.|
 |exit|  |exit|exit's mm and return to menu ('quit' will do the same thing)| |exit|  |exit|exit's mm and return to menu ('quit' will do the same thing)|
-  +\\   
 +==== For multiboard electronics only ==== 
 +^Command^Variables^Usage^Description^ 
 +|E,m| \\ 
 +  m refers to a motor number 
 +  1. Zenith prism 
 +  2. Azimuth Tracker 
 +  3. Iris 
 +  4. Filterwheel 1 
 +  5. Filterwheel 2 
 +  6. Filterwheel 3 or Micrometer 2 (bottom) 
 +  10. Micrometer 1 (Top) 
 +  11. Slitmask 1 
 +  12. Slitmask 2 
 +  13. Zenith tracker 
 +|E,9|This command zeros the motor and return the number it takes to get to the LED. NOTE: This will not return the motor and will leave it at the LED| 
 +|x,s1,s2|s1 and s2 refers to the number of steps to move for micrometer 1 and 2 respectively.|x,100,200|Moves both micrometer 1 and 2 to step s. Note: when moving backwards (negative number) it will set that as the new reference point. [[motor|Click here more motor information]].| 
  
 ==== For new electronics only ==== ==== For new electronics only ====
Line 95: Line 111:
 | |
 |I,9|This commands re-initializes the specified motor| |I,9|This commands re-initializes the specified motor|
 +|N,s|s refers to the number of steps|N,500|(Used for [[singleboard|singleboard electronics]] only.) Moves both micrometer 1 and 2 to step s. Note: when moving backwards (negative number) it will set that as the new reference point. [[motor|Click here more motor information]].|
 |SAVE|   |SAVE|Stores the current set of RAM configuration parameters| |SAVE|   |SAVE|Stores the current set of RAM configuration parameters|
 |?MZ10|   |?MZ10|Runs the command <key>?MOTOR.ZERO.POS[10]</key>| |?MZ10|   |?MZ10|Runs the command <key>?MOTOR.ZERO.POS[10]</key>|
mm.1754936605.txt.gz · Last modified: 2025/08/11 18:23 by reno