User Tools

Site Tools


calsc

This is an old revision of the document!


CALSC

Calibration Sun Scan Schedule

This is a mixed manual and automated schedule. Discreate sun angles interrupt the automated schedule to manually insert sun scans (SC) for Cal Step determination. After a following HG, the schedule then calls the EN routine to automatically insert SL and HG measurements as needed, omits UV measurements; prioritize DS during the remaining time available within the hour and also takes ZS measurements periodically and when the DS measurements are too dim.

This schedule is not in use normally. It was written for calibration purposes.

This is an automated schedule that manually schedules daily diagnostics routines then calls the EC routine to automatically insert SL and HG measurements as needed, takes one TIMED UV measurement per hour; prioritize DS during the remaining time available within the hour and also takes ZS measurements periodically and when the DS measurements are too dim.

This schedule was specifically written to prioritize DS measurements with limited UV and ZS also taken throughout the day. The timed UX for MKIII and timed UF measurements for Single spectrometers are done to create UV files in a format for plotting and critiquing.

calsc.1780060385.txt.gz · Last modified: 2026/05/29 13:13 by mbrohart