ICF ^Name^Description^ |o3 Temp coef 1| Temperature coefficient normalized to zero for slit #1 | |o3 Temp coef 2| Temperature coefficient for slit #2 relative to slit #1 (Slit #2 TC - Slit #1 TC) | |o3 Temp coef 3| Temperature coefficient for slit #3 relative to slit #1 (Slit #3 TC - Slit #1 TC) | |o3 Temp coef 4| Temperature coefficient for slit #4 relative to slit #1 (Slit #4 TC - Slit #1 TC) | |o3 Temp coef 5| Temperature coefficient for slit #5 relative to slit #1 (Slit #5 TC - Slit #1 TC) | |Micrometer steps/deg| | |O3 on O3 Ratio| Absorption value for Ozone | |SO2 on SO2 Ratio| Absorption value for Sulfur dioxide | |O3 on SO2 Ratio| Absorption value for Ozone on the Sulfur dioxide | |ETC on O3 Ratio| The Extraterrestrial Constant (ETC) used for calculating Ozone | |ETC on SO2 Ratio| The Extraterrestrial Constant (ETC) used for calculating Sulfur dioxide| |Dead time (sec)| Dead time the instrument is set to| |WL cal step number| Current cal step for the instrument | |Slitmask Motor Delay|Multi-board electronics - This is the slitmask delay between moving from one slit to the next. The typical value for this is 80\\ New Electronics - This sets the speed of the slitmask motor, typically and usually left at 14.| |Umkehr Offset| Azimuth offset during Umkehr measurements | |ND filter 0| Filer correction from Neutral Density (ND) filter #0 | |ND filter 1| Filer correction from Neutral Density (ND) filter #1 | |ND filter 2| Filer correction from Neutral Density (ND) filter #2 | |ND filter 3| Filer correction from Neutral Density (ND) filter #3 | |ND filter 4| Filer correction from Neutral Density (ND) filter #4 | |ND filter 5| Filer correction from Neutral Density (ND) filter #5 | |Zenith steps/rev| The number of steps to perform a complete rotation of the zenith | |Brewer Type| Version of Brewer spectrophotometer | |COM Port #| Select the comport being used. **if using dosbox or similar dos emulator, this is not the actual comport used on the computer, but the comport specified in the config. Typically left as 1| |o3 Temp coef hg| | |n2 Temp coef hg| | |n2 Temp coef 1| | |n2 Temp coef 2| | |n2 Temp coef 3| | |n2 Temp coef 4| | |n2 Temp coef 5| | |O3 Mic #1 Offset| The number of steps from the bulkhead LED to the micrometer 1 HG test position | |Mic #2 Offset| The number of steps from the bulkhead HED to the micrometer 2 HP test position | |O3 FW #3 Offset| Offset from the filter wheel #3 zero position during Ozone measurements | |NO2 absn Coeff| Absorption value for Nitrogen dioxide | |NO2 ds etc| Direct sun (DS) Extraterrestrial Constant for Nitrogen dioxide measurements | |NO2 zs etc| Zenith sky (ZS) Extraterrestrial Constant for Nitrogen dioxide measurements | |NO2 Mic #1 Offset| Micrometer #1 position in steps for Nitrogen dioxide measurements | |NO2 FW #3 Offset| Filter wheel #3 position in steps for Nitrogen dioxide measurements | |NO2/O3 Mode Change| | |Grating Slope| The relationship of movement between micrometer #1 and micrometer #2 to maximize counts| |Grating Intercept|:::| |Micrometer Zero| | |Iris Open Steps| The number of steps it takes to open the Iris | |Buffer Delay (s)| | |NO2 FW#1 Pos| Position of filter wheel #1 during a Nitrogen dioxide measurement| | O3 FW#1 Pos| Position of filter wheel #1 during Ozone measurements | | SL FW#2 Pos| Position of filter wheel #2 during any tests or measurements that use the standard lamp | | uv FW#2 Pos| Position of filter wheel #2 during a UV measurment | |Zenith Offset| Offset from the zenith zero positioning for optimal pointing | |Zenith UV Pos| Zenith position in steps when performing a UV measurement | |Release date| Date that the ICF was created| |EXTRAS| | |AUTO HG|Allows the software to automatically insert HG as required when running a schedule with auto routine. Typically an HG is ran every 2 hours or a change in temperature of 2 degrees, which ever happens first. \\ 0 - Disable \\ 1 - Enable| |FW2 oscil|Allows filterwheel 2 to keep changing with no limits during DS measurements. This usually happens when the sun gets covered/uncovered by moving clouds.| |HG FW#2 Pos| Position of filter wheel #2 when using the Hg bulb | |Low Signal limit| The number of counts at which the instrument will switch to a lower neutral density filter or skip the test during a direct sun measurement| |Upper Signal limit| The number of counts at which the instrument will increase the neutral density filter during a direct sun measurement| |Use cubic DSP|Enable the use of cubic dispersion. \\ 0 - Disable \\ 1 - Enable| |Skip DS if too dim| Enable skipping a Direct Sun (DS) measurement if counts are too low | |O3ETC-R6| Ozone Extraterrestrial Constant (ETC) minus the R6 standard lamp ratio | |So2ETC-R5| Sulfur dioxide Extraterrestrial Constant (ETC) minus the R5 standard lamp ratio | |PHYCS alpha / slits 2-5 / o3 | PHYCS correction factor for stray light on slits 2 - 5 | |PHYCS beta / slit 1 / so2 | PHYCS correction factor for stray light on slit 1 | |Apply PHYCS| If PHYCS is in use (1=Y, 0=N)| |Updated with CF| |