Critical warnings from b-files' comments for days between 2026184 and 2026184 (0 sec, 2 rows)
| Type | Comment | count | priority | fname | location | serial | time | value | min | max |
| rl: | 2026 183 05 48 04 New value set for watermark SUPPLY.VOLTAGE.HIGH | 13 | 3 | B18426.254 | TORON | #254 | 05:32:03 | | 1 | -1 |
| rl: | 2026 183 06 05 48 New value set for watermark LOOP.RUN.TIME: 673.000050 millisec. | 9 | 3 | B18426.254 | TORON | #254 | 05:32:08 | | 1 | -1 |
Instrument constant changes for the week before 2026184 (4 sec, 0 rows)
Non-critical warnings from b-files' comments for days between 2026184 and 2026184 (0 sec, 5 rows)
| Type | Comment | count | priority | fname | location | serial | time | value | min | max |
| rl: | 2026 183 05 47 29 Reset Warm -> Tepid from 2026 183 05 47 24 until 2026 183 05 47 24 . Counts: 1,0 | 1 | 3 | B18426.254 | TORON | #254 | 05:32:00 | | 1 | -1 |
| rl: | 2026 183 05 48 04 New value set for watermark SUPPLY.VOLTAGE.HIGH | 3 | 3 | B18426.254 | TORON | #254 | 05:32:03 | | 1 | -1 |
| rl: | 2026 183 06 05 48 New value set for watermark LOOP.RUN.TIME: 673.000050 millisec. | 1 | 3 | B18426.254 | TORON | #254 | 05:32:08 | | 1 | -1 |
| sc: | SC intensity too low ( 336/cy), skipping. | 1 | 3 | B18426.254 | TORON | #254 | 12:21:06 | | 1 | -1 |
| sc: | Suppressed oscillation of filter wheel. | 4 | 5 | B18426.254 | TORON | #254 | 13:52:32 | | 1 | -1 |
Measurements and tests summary.
| _jday | _loc | _serial | _skc | ds | dt | ed | fm | fz | hg | hp | rs | sl | uv | zs |
| 184 | TORONTO | #254 | calsc,Next schedule will be calsc (now calsc ZS= 90 ZS= 91.052),Next schedule will be calsc (now calsc ZS= 90 ZS= 91.636) | 121 | 1 | 2 | 2 | 3 | 31 | 34 | 1 | 6 | 6 | 19 |
(0 sec)
Number of days since last dome/window cleaning (0 sec, 1 rows)
Missing files (0 sec, 1 rows)
| Serial | last data | days ago |
| 254 | 2026185 | 0-1 |
Run/Stop results for last week. (0 sec, 1 rows)
| Serial | Total | Failed 0 | Failed dark | Failed 1 | Failed 2 | Failed 3 | Failed 4 | Failed 5 | Failed double |
| 254 | 11 | 0 | 2 | 0 | 0 | 0 | 0 | 0 | 0 |
AP results for SB Brewers. (0 sec, 1 rows)
| Serial | Jday | t1 off | t1 on | t2 off | t2 on | t3 off | t3 on | HV off | HV on | +12V off | +12V on | +5V off | +5V on | -12V off | -12V on | +24V off | +24V on | +5V sps off | +5V sps on | SL A off | SL A on | SL V off | SL V on | Watts |
| 254 | 2026184 | 36.1 | 36.0 | 36.0 | 35.8 | 35.0 | 34.8 | 1388.4 | 1388.2 | 12.1 | 12.1 | 5.1 | 5.1 | -12.0 | -12.0 | 24.3 | 24.3 | 5.0 | 5.0 | 0.0 | 1.5 | 0.0 | 10.06 | 15.6 |
Standard lamp intensity analysis (0 sec, 1 rows)
| Serial | min | max | filter | fixable | 30-day history |
| #254 | 2187310 | 2187310 | 0 | yes |