Database last updated on Tue, 27 Jan 2026 13:40:49 +0000 by localhost
Critical warnings from b-files' comments for days between 2025078 and 2025078 (0 sec, 3 rows)
| Type | Comment | count | priority | fname | location | serial | time | value | min | max |
| rl: | 2025 078 05 45 48 New value set for watermark SUPPLY.VOLTAGE.HIGH | 9 | 3 | B07825.254 | TORON | #254 | 05:34:59 | | 1 | -1 |
| rl: | 2025 078 06 01 36 PMT counter failure | 1 | 1 | B07825.254 | TORON | #254 | 05:35:03 | | 1 | -1 |
| rl: | 2025 078 06 05 07 New value set for watermark LOOP.RUN.TIME: 699.000025 millisec. | 7 | 3 | B07825.254 | TORON | #254 | 05:35:06 | | 1 | -1 |
Instrument constant changes for the week before 2025078 (1 sec, 0 rows)
SL burned out? (AP results when SL is ON) (0 sec, 8 rows)
Non-critical warnings from b-files' comments for days between 2025078 and 2025078 (0 sec, 3 rows)
| Type | Comment | count | priority | fname | location | serial | time | value | min | max |
| rl: | 2025 078 05 44 45 Reset Warm -> Tepid from 2025 078 05 44 39 until 2025 078 05 44 40 . Counts: 1,0 | 1 | 3 | B07825.254 | TORON | #254 | 05:34:53 | | 1 | -1 |
| rl: | 2025 078 05 44 51 Reset No -> Warm from 2025 078 05 44 48 until 2025 078 05 44 48 . Counts: 1,1 | 1 | 3 | B07825.254 | TORON | #254 | 05:34:56 | | 1 | -1 |
| re: | Zenith discrepancy = -143 | 1 | 99 | B07825.254 | TORON | #254 | 05:39:35 | -143 | -10 | 10 |
Measurements and tests summary.
| _jday | _loc | _serial | _skc | ds | dt | ed | fm | fz | hg | hp | rs | sl | uv | zs |
| 078 | TORONTO | #254 | ecsc,Next schedule will be ecsc (now ecsc ZS= 93 ZS= 93.602) | 76 | 2 | 2 | 19 | 4 | 19 | 19 | 2 | 7 | 27 | 23 |
(0 sec)
Number of days since last dome/window cleaning (0 sec, 1 rows)
Missing files (0 sec, 1 rows)
| Serial | last data | days ago |
| 254 | 2025079 | 0-1 |
Run/Stop results for last week. (0 sec, 1 rows)
| Serial | Total | Failed 0 | Failed dark | Failed 1 | Failed 2 | Failed 3 | Failed 4 | Failed 5 | Failed double |
| 254 | 11 | 0 | 1 | 0 | 0 | 0 | 0 | 0 | 0 |
AP results for SB Brewers. (0 sec, 1 rows)
| Serial | Jday | t1 off | t1 on | t2 off | t2 on | t3 off | t3 on | HV off | HV on | +12V off | +12V on | +5V off | +5V on | -12V off | -12V on | +24V off | +24V on | +5V sps off | +5V sps on | SL A off | SL A on | SL V off | SL V on | Watts |
| 254 | 2025078 | 16.9 | 17.2 | 16.7 | 17.0 | 16.5 | 16.5 | 1389.8 | 1389.8 | 12.1 | 12.1 | 5.1 | 5.1 | -12.0 | -12.0 | 24.2 | 24.2 | 5.0 | 5.0 | 0.0 | 1.5 | 0.0 | 10.13 | 15.7 |
Standard lamp intensity analysis (0 sec, 1 rows)
| Serial | min | max | filter | fixable | 30-day history |
| #254 | 2510760 | 2512900 | 0 | yes |