Database last updated on Tue, 10 Feb 2026 17:10:55 +0000 by localhost

Critical warnings from b-files' comments for days between 2021106 and 2021106 (0 sec, 1 rows)

TypeCommentcountpriorityfnamelocationserialtimevalueminmax
rl:2021 105 06 34 37 Motor #11: appears stuck with a reference sensor activated.11B10621.239CHURC#23906:27:271-1

Instrument constant changes for the week before 2021106 (2 sec, 0 rows)

Non-critical warnings from b-files' comments for days between 2021106 and 2021106 (0 sec, 7 rows)

TypeCommentcountpriorityfnamelocationserialtimevalueminmax
rl:2021 105 06 34 36 Reset Warm -> Tepid from 2021 105 06 34 30 until 2021 105 06 34 31 . Counts: 1,013B10621.239CHURC#23906:27:241-1
rl:2021 105 06 34 37 Motor #11: appears stuck with a reference sensor activated.13B10621.239CHURC#23906:27:271-1
rl:2021 105 06 56 02 New value set for watermark LOOP.RUN.TIME: 711.999989 millisec.13B10621.239CHURC#23906:27:291-1
rl:2021 105 06 56 02 New value set for watermark LOOP.RUN.TIME: 711.999989 millisec.13B10621.239CHURC#23906:27:291-1
rl:2021 106 00 41 22 New value set for watermark LOOP.RUN.TIME: 714.000034 millisec.13B10621.239CHURC#23906:27:321-1
rl:2021 106 00 41 22 New value set for watermark LOOP.RUN.TIME: 714.000034 millisec.13B10621.239CHURC#23906:27:321-1
zs:ZS intensity too low ( 90/cy), skipping.499B10621.239CHURC#23910:54:241-1

Measurements and tests summary.


_jday_loc_serial_skcaodedsdtedfzhghprssluvzs
106CHURCHILL#239ecsc,Next schedule will be ecsc (now ecsc ZS= 93 ZS= 93.15899)37372231516276423
(0 sec)

Number of days since last dome/window cleaning (0 sec, 3 rows)

serialdays
3more than a year
239more than a year

Missing files (0 sec, 1 rows)

Seriallast datadays ago
23920211070-1

Run/Stop results for last week. (0 sec, 1 rows)

SerialTotalFailed 0Failed darkFailed 1Failed 2Failed 3Failed 4Failed 5Failed double
2391605000000

AP results for SB Brewers. (0 sec, 1 rows)

SerialJdayt1 offt1 ont2 offt2 ont3 offt3 onHV offHV on+12V off+12V on+5V off+5V on-12V off-12V on+24V off+24V on+5V sps off+5V sps onSL A offSL A onSL V offSL V onWatts
23920211067.96.97.86.83.93.41351.31182.212.010.55.04.4-12.0-10.524.621.25.04.40.01.30.09.5113.8

Standard lamp intensity analysis (0 sec, 1 rows)

Serialminmaxfilterfixable30-day history
#239215116021546000yes