Database last updated on Tue, 08 Sep 2026 06:11:01 +0000 by localhost

Critical warnings from b-files' comments for days between 2020192 and 2020192 (0 sec, 3 rows)

TypeCommentcountpriorityfnamelocationserialtimevalueminmax
rl:2020 191 06 27 28 Motor #11: appears stuck with a reference sensor activated.11B19220.239CHURC#23906:25:131-1
rl:2020 191 06 44 07 New value set for watermark LOOP.RUN.TIME: 699.000025 millisec.63B19220.239CHURC#23906:25:141-1
rl:2020 191 06 44 07 New value set for watermark LOOP.RUN.TIME: 699.000025 millisec.63B19220.239CHURC#23906:25:141-1

Instrument constant changes for the week before 2020192 (3 sec, 0 rows)

Hg with step corrections larger than 10 steps or multiple corrections larger than 2.5 steps (0 sec, 1 rows)

SerialYYYYJJJHG largemax correction
2392020192111.1

Non-critical warnings from b-files' comments for days between 2020192 and 2020192 (0 sec, 4 rows)

TypeCommentcountpriorityfnamelocationserialtimevalueminmax
rl:2020 191 06 27 27 Reset Warm -> Tepid from 2020 191 06 27 21 until 2020 191 06 27 22 . Counts: 1,013B19220.239CHURC#23906:25:121-1
rl:2020 191 06 27 28 Motor #11: appears stuck with a reference sensor activated.13B19220.239CHURC#23906:25:131-1
rl:2020 192 08 55 34 New value set for watermark LOOP.RUN.TIME: 724.000025 millisec.13B19220.239CHURC#23906:25:211-1
rl:2020 192 08 55 34 New value set for watermark LOOP.RUN.TIME: 724.000025 millisec.13B19220.239CHURC#23906:25:211-1

Measurements and tests summary.


_jday_loc_serial_skcaodedsdtedfzhghprssluvzs
192CHURCHILL#239ecsc90902161010158021
(0 sec)

Number of days since last dome/window cleaning (0 sec, 3 rows)

serialdays
3more than a year
239216

Missing files (0 sec, 1 rows)

Seriallast datadays ago
23920201930-1

Run/Stop results for last week. (0 sec, 1 rows)

SerialTotalFailed 0Failed darkFailed 1Failed 2Failed 3Failed 4Failed 5Failed double
2391407000000

AP results for SB Brewers. (0 sec, 1 rows)

SerialJdayt1 offt1 ont2 offt2 ont3 offt3 onHV offHV on+12V off+12V on+5V off+5V on-12V off-12V on+24V off+24V on+5V sps off+5V sps onSL A offSL A onSL V offSL V onWatts
239202019214.614.614.614.613.313.31350.71351.312.012.05.05.0-12.0-12.024.624.25.05.00.01.30.010.7714.3

Standard lamp intensity analysis (0 sec, 1 rows)

Serialminmaxfilterfixable30-day history
#239211345021190600yes