Database last updated on Fri, 11 Sep 2026 01:41:02 +0000 by localhost

Critical warnings from b-files' comments for days between 2019338 and 2019338 (0 sec, 3 rows)

TypeCommentcountpriorityfnamelocationserialtimevalueminmax
rl:2019 337 06 11 48 Motor #11: appears stuck with a reference sensor activated.11B33819.239CHURC#23906:10:351-1
rl:2019 337 06 28 33 New value set for watermark LOOP.RUN.TIME: 673.000050 millisec.83B33819.239CHURC#23906:10:361-1
rl:2019 337 06 28 33 New value set for watermark LOOP.RUN.TIME: 673.000050 millisec.83B33819.239CHURC#23906:10:361-1

Instrument constant changes for the week before 2019338 (2 sec, 0 rows)

SL burned out? (AP results when SL is ON) (0 sec, 32 rows)

SerialYYYYJJJSL CurrentSL Voltage
2392019331-12.0124.25
2392019332-11.9924.25
2392019333-11.9924.22
2392019334-11.9924.22
2392019335-12.0124.25
2392019336-12.0124.22
2392019337-11.9924.22
2392019338-11.9924.25

Non-critical warnings from b-files' comments for days between 2019338 and 2019338 (0 sec, 5 rows)

TypeCommentcountpriorityfnamelocationserialtimevalueminmax
rl:2019 337 06 11 46 Reset Warm -> Tepid from 2019 337 06 11 41 until 2019 337 06 11 41 . Counts: 1,013B33819.239CHURC#23906:10:331-1
rl:2019 337 06 11 48 Motor #11: appears stuck with a reference sensor activated.13B33819.239CHURC#23906:10:351-1
rl:2019 338 00 38 18 New value set for watermark LOOP.RUN.TIME: 723.000050 millisec.13B33819.239CHURC#23906:10:461-1
rl:2019 338 00 38 18 New value set for watermark LOOP.RUN.TIME: 723.000050 millisec.13B33819.239CHURC#23906:10:461-1
zs:ZS intensity too low ( 396/cy), skipping.499B33819.239CHURC#23921:12:291-1

Measurements and tests summary.


_jday_loc_serial_skcaodedsdtedfmfzhghprssluvzs
338CHURCHILL#239ecsc1111211981211262630
(0 sec)

Number of days since last dome/window cleaning (0 sec, 3 rows)

serialdays
3more than a year
239027

Missing files (0 sec, 1 rows)

Seriallast datadays ago
23920193390-1

Run/Stop results for last week. (0 sec, 1 rows)

SerialTotalFailed 0Failed darkFailed 1Failed 2Failed 3Failed 4Failed 5Failed double
2391704000000

AP results for MB Brewer. (0 sec, 1 rows)

SerialJdayt1 offt1 ont2 offt2 ont3 offt3 onHV offHV on+15V off+15V on+5V off+5V on-15V off-15V on+24V off+24V on+5V sps off+5V sps on-8V sps off-8V sps onSL A offSL A onSL V offSL V onW
23920193387.60.07.30.0-1.01.31350.91.912.06.95.00.5-12.02.024.72.25.012.0-5.05.00.0-12.00.024.24-290.8

Standard lamp intensity analysis (0 sec, 1 rows)

Serialminmaxfilterfixable30-day history
#239212481021303900yes