Database last updated on Sun, 01 Feb 2026 14:10:54 +0000 by localhost
Critical warnings from b-files' comments for days between 2023283 and 2023283 (0 sec, 1 rows)
| Type | Comment | count | priority | fname | location | serial | time | value | min | max |
| rl: | 2023 276 16 23 36 Motor #3: appears stuck with a reference sensor activated. | 2 | 1 | B28323.235 | RESOL | #235 | 06:19:13 | | 1 | -1 |
Instrument constant changes for the week before 2023283 (3 sec, 0 rows)
SL burned out? (AP results when SL is ON) (0 sec, 1 rows)
HG burned out? (AP results when HG is ON) (0 sec, 16 rows)
Non-critical warnings from b-files' comments for days between 2023283 and 2023283 (0 sec, 5 rows)
| Type | Comment | count | priority | fname | location | serial | time | value | min | max |
| rl: | 2023 276 16 23 36 Motor #3: appears stuck with a reference sensor activated. | 1 | 3 | B28323.235 | RESOL | #235 | 06:19:13 | | 1 | -1 |
| rl: | 2023 276 16 23 36 Motor #11: appears stuck with a reference sensor activated. | 1 | 3 | B28323.235 | RESOL | #235 | 06:19:16 | | 1 | -1 |
| rl: | 2023 283 10 56 39 New value set for watermark LOOP.RUN.TIME: 674.000025 millisec. | 2 | 3 | B28323.235 | RESOL | #235 | 06:19:19 | | 1 | -1 |
| rl: | 2023 283 10 56 39 New value set for watermark LOOP.RUN.TIME: 674.000025 millisec. | 2 | 3 | B28323.235 | RESOL | #235 | 06:19:19 | | 1 | -1 |
| ab_sk: | HOME key pressed | 1 | 99 | B28323.235 | RESOL | #235 | 10:55:55 | | 1 | -1 |
Measurements and tests summary.
| _jday | _loc | _serial | _skc | dt | ed | fz | hg | hp | rs | sl | uv | zs |
| 283 | RESOLUTE | #235 | ecsc,Next schedule will be ecsc (now ecsc ZS= 93 ZS= 93.38301) | 1 | 2 | 4 | 12 | 11 | 1 | 6 | 47 | 28 |
(0 sec)
Number of days since last dome/window cleaning (0 sec, 3 rows)
| serial | days |
| 3 | more than a year |
| 235 | more than a year |
Missing files (0 sec, 1 rows)
| Serial | last data | days ago |
| 235 | 2023284 | 0-1 |
Run/Stop results for last week. (0 sec, 1 rows)
| Serial | Total | Failed 0 | Failed dark | Failed 1 | Failed 2 | Failed 3 | Failed 4 | Failed 5 | Failed double |
| 235 | 2 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
AP results for SB Brewers. (0 sec, 1 rows)
| Serial | Jday | t1 off | t1 on | t2 off | t2 on | t3 off | t3 on | HV off | HV on | +12V off | +12V on | +5V off | +5V on | -12V off | -12V on | +24V off | +24V on | +5V sps off | +5V sps on | SL A off | SL A on | SL V off | SL V on | Watts |
| 235 | 2023283 | 16.5 | 16.5 | 16.7 | 16.7 | 11.6 | 11.6 | 1427.8 | 1427.8 | 12.0 | 12.0 | 5.0 | 5.0 | -11.9 | -11.9 | 24.5 | 23.7 | 5.0 | 5.0 | 0.0 | 1.5 | 0.0 | 10.99 | 16.7 |
Standard lamp intensity analysis (0 sec, 1 rows)
| Serial | min | max | filter | fixable | 30-day history |
| #235 | 1247660 | 1247660 | 0 | |