| Type | Comment | count | priority | fname | location | serial | time | value | min | max |
|---|---|---|---|---|---|---|---|---|---|---|
| rl: | 2025 219 23 58 35 Motor #3: appears stuck with a reference sensor activated. | 3 | 1 | B21925.224 | TORON | #224 | 05:32:44 | 1 | -1 | |
| rl: | 2025 219 04 28 35 New value set for watermark SUPPLY.VOLTAGE.HIGH | 7 | 3 | B21925.224 | TORON | #224 | 05:32:52 | 1 | -1 |
| Serial | YYYYJJJ | HG large | max correction |
|---|---|---|---|
| 224 | 2025219 | 3 | 13.7 |
| Type | Comment | count | priority | fname | location | serial | time | value | min | max |
|---|---|---|---|---|---|---|---|---|---|---|
| rl: | 2025 219 23 58 34 Reset No -> Tepid from 2025 219 23 58 25 until 2103 183 17 30 13 . Counts: 1,0 | 1 | 3 | B21925.224 | TORON | #224 | 05:32:40 | 1 | -1 | |
| rl: | 2025 219 23 58 35 Checksum bad in low level command. | 1 | 3 | B21925.224 | TORON | #224 | 05:32:42 | 1 | -1 | |
| rl: | 2025 219 23 58 35 Motor #3: appears stuck with a reference sensor activated. | 1 | 3 | B21925.224 | TORON | #224 | 05:32:44 | 1 | -1 | |
| rl: | 2025 219 23 58 35 Motor #11: appears stuck with a reference sensor activated. | 1 | 3 | B21925.224 | TORON | #224 | 05:32:47 | 1 | -1 | |
| ux: | HOME key pressed | 1 | 99 | B21925.224 | TORON | #224 | 14:40:40 | 1 | -1 | |
| ux: | UV extended scan aborted | 1 | 3 | B21925.224 | TORON | #224 | 14:40:43 | 1 | -1 | |
| pd: | Going to menu | 1 | 99 | B21925.224 | TORON | #224 | 14:41:11 | 1 | -1 | |
| sr: | Azimuth discrepancy = 230 | 1 | 99 | B21925.224 | TORON | #224 | 14:44:51 | 230 | -30 | 30 |
| si: | New SI, HC = 8, NC = 210 Old = 8 , 220. SZA= 42.028 | 1 | 99 | B21925.224 | TORON | #224 | 14:53:18 | 1 | -1 | |
| zs: | ZS is not done when solar zenith angle less than 30 degrees. Skipping. | 1 | 10 | B21925.224 | TORON | #224 | 16:40:21 | 1 | -1 | |
| ds: | DS intensity too high ( 203265/cy) quitting. | 3 | 99 | B21925.224 | TORON | #224 | 16:48:58 | 1 | -1 |
| _jday | _loc | _serial | _skc | ds | dt | ed | fm | fz | hg | hp | rs | sl | uv | zs |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 219 | TORONTO | #224 | ecsc,Next schedule will be ecsc (now ecsc ZS= 93 ZS= 93.137) | 98 | 2 | 2 | 10 | 9 | 28 | 24 | 2 | 4 | 30 | 25 |
| serial | days |
|---|---|
| 224 | more than a year |
| Serial | last data | days ago |
|---|---|---|
| 224 | 2025220 | 0-1 |
| Serial | Total | Failed 0 | Failed dark | Failed 1 | Failed 2 | Failed 3 | Failed 4 | Failed 5 | Failed double |
|---|---|---|---|---|---|---|---|---|---|
| 224 | 16 | 0 | 1 | 0 | 0 | 0 | 0 | 0 | 0 |
| Serial | Jday | t1 off | t1 on | t2 off | t2 on | t3 off | t3 on | HV off | HV on | +12V off | +12V on | +5V off | +5V on | -12V off | -12V on | +24V off | +24V on | +5V sps off | +5V sps on | SL A off | SL A on | SL V off | SL V on | Watts |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 224 | 2025219 | 26.5 | 26.5 | 27.3 | 27.3 | 26.5 | 26.5 | 1275.4 | 1274.3 | 12.0 | 12.0 | 5.1 | 5.1 | -12.0 | -12.0 | 24.1 | 24.1 | 5.1 | 5.1 | 0.0 | 1.5 | 0.0 | 10.54 | 15.9 |
| Serial | min | max | filter | fixable | 30-day history |
|---|---|---|---|---|---|
| #224 | 2666940 | 2670610 | 0 | yes |