Critical warnings from b-files' comments for days between 2025055 and 2025055 (0 sec, 4 rows)

TypeCommentcountpriorityfnamelocationserialtimevalueminmax
rl:2025 055 13 50 07 Motor #3: appears stuck with a reference sensor activated.31B05525.224TORON#22405:41:141-1
rl:2025 055 14 01 36 New value set for watermark SUPPLY.VOLTAGE.HIGH123B05525.224TORON#22405:41:231-1
fr:11000 steps - QUIT - Micrometer #1 reference not found11B05525.224TORON#22406:33:251-1
pd:Command file pd not found --- continuing11B05525.224TORON#22413:54:001-1

Instrument constant changes for the week before 2025055 (2 sec, 0 rows)

SL burned out? (AP results when SL is ON) (0 sec, 5 rows)

SerialYYYYJJJSL CurrentSL Voltage
2242025049012.83
22420250541.5110.46
22420250551.5110.44

HG burned out? (AP results when HG is ON) (0 sec, 1 rows)

Hg with step corrections larger than 10 steps or multiple corrections larger than 2.5 steps (0 sec, 1 rows)

SerialYYYYJJJHG largemax correction
2242025055423.1

HP with step corrections larger than 20 steps (0 sec, 1 rows)

SerialYYYYJJJHP largemax correction
2242025055227.2

Non-critical warnings from b-files' comments for days between 2025055 and 2025055 (0 sec, 7 rows)

TypeCommentcountpriorityfnamelocationserialtimevalueminmax
rl:2025 055 13 50 06 Reset No -> Tepid from 2025 055 13 46 07 until 2085 019 07 21 45 . Counts: 1,013B05525.224TORON#22405:41:091-1
rl:2025 055 13 50 07 Checksum bad in low level command.13B05525.224TORON#22405:41:111-1
rl:2025 055 13 50 07 Motor #3: appears stuck with a reference sensor activated.13B05525.224TORON#22405:41:141-1
rl:2025 055 13 50 07 Motor #11: appears stuck with a reference sensor activated.13B05525.224TORON#22405:41:161-1
dp:Doing dispersion with internal HG.199B05525.224TORON#22411:11:151-1
pd:Command file pd not found --- continuing199B05525.224TORON#22413:54:00continuing1-1
ds:DS intensity too high ( 227514/cy) quitting.299B05525.224TORON#22417:31:491-1

Measurements and tests summary.


_jday_loc_serial_skcdsdtedfzhghprssluvzs
055TORONTO#224inside,menu,Next schedule will be ecsc (now ecsc ZS= 93 ZS= 93.444),Saving backup OP,Starting schedule ecsc,Waiting until ZA = -100 now -101.8,Waiting until ZA = -110 now -111.7,Waiting until ZA = -110 now -113.5,Waiting until ZA = -110 now -115.3,Waiting until ZA = -110 now -117.1,Waiting until ZA = -110 now -118.8,Waiting until ZA = -110 now -120.6,Waiting until ZA = -110 now -122.3,Waiting until ZA = -110 now -124,Waiting until ZA = -110 now -125.7,Waiting until ZA = -110 now -127.3,Waiting until ZA = -110 now -128.9,Waiting until ZA = -110 now -130.5,Waiting until ZA = -110 now -132.1,Waiting until ZA = -110 now -133.5,Waiting until ZA = -85 now -88.9,Waiting until ZA = -85 now -91.1,Waiting until ZA = -85 now -92.9432231918262132
(0 sec)

Number of days since last dome/window cleaning (0 sec, 2 rows)

serialdays
224more than a year

Missing files (0 sec, 1 rows)

Seriallast datadays ago
22420250560-1

Run/Stop results for last week. (0 sec, 1 rows)

SerialTotalFailed 0Failed darkFailed 1Failed 2Failed 3Failed 4Failed 5Failed double
2246605000000

AP results for SB Brewers. (0 sec, 1 rows)

SerialJdayt1 offt1 ont2 offt2 ont3 offt3 onHV offHV on+12V off+12V on+5V off+5V on-12V off-12V on+24V off+24V on+5V sps off+5V sps onSL A offSL A onSL V offSL V onWatts
224202505518.318.319.819.818.118.01276.51275.512.012.05.25.2-12.4-12.424.124.15.05.00.01.50.010.4615.8

Standard lamp intensity analysis (0 sec, 1 rows)

Serialminmaxfilterfixable30-day history
#224262657026323700yes