Database last updated on Sun, 01 Feb 2026 14:40:50 +0000 by localhost

Critical warnings from b-files' comments for days between 2024110 and 2024110 (0 sec, 2 rows)

TypeCommentcountpriorityfnamelocationserialtimevalueminmax
rl:2024 109 05 29 40 Motor #1: appears stuck with a reference sensor activated.31#22405:24:071-1
rl:2024 110 17 33 00 New value set for watermark SUPPLY.VOLTAGE.LOW[53#22405:24:141-1

Instrument constant changes for the week before 2024110 (3 sec, 0 rows)

SL burned out? (AP results when SL is ON) (0 sec, 2 rows)

Hg with step corrections larger than 10 steps or multiple corrections larger than 2.5 steps (0 sec, 1 rows)

SerialYYYYJJJHG largemax correction
2242024110117.0

Non-critical warnings from b-files' comments for days between 2024110 and 2024110 (0 sec, 3 rows)

TypeCommentcountpriorityfnamelocationserialtimevalueminmax
rl:2024 109 05 29 40 Motor #1: appears stuck with a reference sensor activated.13#22405:24:071-1
sc:SC intensity too low ( 33/cy), skipping.33#22411:57:001-1
ds:Suppressed oscillation of filter wheel.45#22417:24:381-1

Measurements and tests summary.


_jday_loc_serial_skcdsdtedfmfzhghprssluvzs
110TORONTO#224calsc,Next schedule will be calsc (now calsc ZS= 90 ZS= 91.245),Next schedule will be calsc (now calsc ZS= 90 ZS= 91.88301)88222132222261616
(0 sec)

Number of days since last dome/window cleaning (0 sec, 2 rows)

serialdays
224more than a year

Run/Stop results for last week. (0 sec, 1 rows)

SerialTotalFailed 0Failed darkFailed 1Failed 2Failed 3Failed 4Failed 5Failed double
224600000000

AP results for SB Brewers. (0 sec, 1 rows)

SerialJdayt1 offt1 ont2 offt2 ont3 offt3 onHV offHV on+12V off+12V on+5V off+5V on-12V off-12V on+24V off+24V on+5V sps off+5V sps onSL A offSL A onSL V offSL V onWatts
224202411017.117.119.319.315.215.21316.01314.912.012.05.15.1-12.3-12.324.124.15.05.00.01.50.010.7816.3

Standard lamp intensity analysis (0 sec, 1 rows)

Serialminmaxfilterfixable30-day history
#224392286039238900yes