Critical warnings from b-files' comments for days between 2024051 and 2024051 (0 sec, 1 rows)
| Type | Comment | count | priority | fname | location | serial | time | value | min | max |
| rl: | 2024 051 19 24 38 Motor #2: appears stuck with a reference sensor activated. | 7 | 1 | B05124.224 | TORON | #224 | 05:44:38 | | 1 | -1 |
Instrument constant changes for the week before 2024051 (1 sec, 0 rows)
HG burned out? (AP results when HG is ON) (0 sec, 13 rows)
Non-critical warnings from b-files' comments for days between 2024051 and 2024051 (0 sec, 7 rows)
| Type | Comment | count | priority | fname | location | serial | time | value | min | max |
| rl: | 2024 051 14 36 56 New value set for watermark SUPPLY.VOLTAGE.LOW[ | 1 | 3 | B05124.224 | TORON | #224 | 05:44:36 | | 1 | -1 |
| rl: | 2024 051 19 25 42 Motor #1: appears stuck with a reference sensor activated. | 1 | 3 | B05124.224 | TORON | #224 | 05:44:41 | | 1 | -1 |
| rl: | 2024 052 00 00 14 New value set for watermark SUPPLY.VOLTAGE.LOW[ | 3 | 3 | B05124.224 | TORON | #224 | 05:44:54 | | 1 | -1 |
| ds: | HOME key pressed | 1 | 99 | B05124.224 | TORON | #224 | 19:22:38 | | 1 | -1 |
| pd: | Going to menu | 1 | 99 | B05124.224 | TORON | #224 | 19:22:43 | | 1 | -1 |
| az: | Azimuth discrepancy = 4675 | 1 | 99 | B05124.224 | TORON | #224 | 19:24:41 | 4675 | -30 | 30 |
| si: | New SI, HC = | 1 | 99 | B05124.224 | TORON | #224 | 19:31:00 | | 1 | -1 |
Measurements and tests summary.
| _jday | _loc | _serial | _skc | ds | dt | ed | fm | fz | hg | hp | rs | sl | uv | zs |
| 051 | TORONTO | #224 | ecsc,Next schedule will be ecsc (now ecsc ZS= 93 ZS= 93.572) | 58 | 1 | 2 | 40 | 12 | 19 | 18 | 1 | 5 | 2 | 42 |
(1 sec)
Number of days since last dome/window cleaning (0 sec, 2 rows)
| serial | days |
| 224 | more than a year |
Missing files (0 sec, 1 rows)
| Serial | last data | days ago |
| 224 | 2024052 | 0-1 |
Run/Stop results for last week. (0 sec, 1 rows)
| Serial | Total | Failed 0 | Failed dark | Failed 1 | Failed 2 | Failed 3 | Failed 4 | Failed 5 | Failed double |
| 224 | 35 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
AP results for SB Brewers. (0 sec, 1 rows)
| Serial | Jday | t1 off | t1 on | t2 off | t2 on | t3 off | t3 on | HV off | HV on | +12V off | +12V on | +5V off | +5V on | -12V off | -12V on | +24V off | +24V on | +5V sps off | +5V sps on | SL A off | SL A on | SL V off | SL V on | Watts |
| 224 | 2024051 | 0.4 | 0.4 | 0.8 | 0.8 | 0.1 | 0.1 | 1165.0 | 1163.5 | 12.0 | 12.0 | 5.2 | 5.2 | -12.4 | -12.4 | 24.1 | 24.1 | 5.0 | 5.0 | 0.0 | 1.5 | 0.0 | 10.74 | 16.2 |
Standard lamp intensity analysis (0 sec, 1 rows)
| Serial | min | max | filter | fixable | 30-day history |
| #224 | 2823310 | 2823310 | 0 | yes |