Critical warnings from b-files' comments for days between 2024046 and 2024046 (0 sec, 4 rows)

TypeCommentcountpriorityfnamelocationserialtimevalueminmax
rl:2024 046 15 57 44 Motor #3: appears stuck with a reference sensor activated.21B04624.224TORON#22405:37:321-1
rl:2024 046 15 59 53 New value set for watermark SUPPLY.VOLTAGE.HIGH[163B04624.224TORON#22405:37:391-1
re:Reset failed 5 times. Quitting and going to the menu.11B04624.224TORON#22416:13:201-1
pd:Brewer failed to respond 5 times11B04624.224TORON#22416:15:341-1

Instrument constant changes for the week before 2024046 (2 sec, 0 rows)

HG burned out? (AP results when HG is ON) (0 sec, 14 rows)

Hg with step corrections larger than 10 steps or multiple corrections larger than 2.5 steps (0 sec, 1 rows)

SerialYYYYJJJHG largemax correction
22420240461626.7

HP with step corrections larger than 20 steps (0 sec, 1 rows)

SerialYYYYJJJHP largemax correction
22420240462380.0

Non-critical warnings from b-files' comments for days between 2024046 and 2024046 (0 sec, 7 rows)

TypeCommentcountpriorityfnamelocationserialtimevalueminmax
rl:2024 046 15 57 43 Checksum bad in low level command.13B04624.224TORON#22405:37:301-1
rl:2024 046 15 57 44 Motor #3: appears stuck with a reference sensor activated.13B04624.224TORON#22405:37:321-1
rl:2024 046 15 57 44 Motor #11: appears stuck with a reference sensor activated.13B04624.224TORON#22405:37:341-1
rl:2024 046 15 59 52 MAIN.C : motor initialization timed out.15B04624.224TORON#22405:37:361-1
dp:Doing dispersion with internal HG.199B04624.224TORON#22411:25:251-1
hp:HOME key pressed199B04624.224TORON#22415:48:421-1
pd:Going to menu199B04624.224TORON#22415:49:161-1

Measurements and tests summary.


_jday_loc_serial_skcdtedfzhghprssluvzs
046TORONTO#224inside,Must do HG now,Next schedule will be ecsc (now ecsc ZS= 93 ZS= 93.344),Saving backup OP_ST.000,Starting schedule ecsc,Waiting until ZA =42849764624
(0 sec)

Number of days since last dome/window cleaning (0 sec, 2 rows)

serialdays
224more than a year

Run/Stop results for last week. (0 sec, 1 rows)

SerialTotalFailed 0Failed darkFailed 1Failed 2Failed 3Failed 4Failed 5Failed double
2249303000001

AP results for SB Brewers. (0 sec, 1 rows)

SerialJdayt1 offt1 ont2 offt2 ont3 offt3 onHV offHV on+12V off+12V on+5V off+5V on-12V off-12V on+24V off+24V on+5V sps off+5V sps onSL A offSL A onSL V offSL V onWatts
224202404617.317.318.518.516.816.91165.41164.212.012.05.25.2-11.8-11.824.124.15.05.00.01.50.010.7816.3

Standard lamp intensity analysis (0 sec, 1 rows)

Serialminmaxfilterfixable30-day history
#224266626026768200yes