Database last updated on Mon, 02 Feb 2026 01:40:53 +0000 by localhost

Critical warnings from b-files' comments for days between 2024032 and 2024032 (0 sec, 3 rows)

TypeCommentcountpriorityfnamelocationserialtimevalueminmax
rl:2024 031 16 09 16 Motor #3: appears stuck with a reference sensor activated.41B03224.224TORON#22405:33:251-1
rl:2024 031 17 33 19 New value set for watermark SUPPLY.VOLTAGE.HIGH[103B03224.224TORON#22405:33:361-1
skc:Azimuth drive turned OFF in op_st.62B03224.224TORON#22415:11:111-1

Instrument constant changes for the week before 2024032 (3 sec, 0 rows)

HG burned out? (AP results when HG is ON) (0 sec, 18 rows)

SerialYYYYJJJHG CurrentHG Voltage
2242024030013.7
22420240310.3212.16
22420240310.4612.86
22420240320.4612.86
22420240320.4612.88
22420240320.4612.85

Hg with step corrections larger than 10 steps or multiple corrections larger than 2.5 steps (0 sec, 1 rows)

SerialYYYYJJJHG largemax correction
2242024032164.2

Non-critical warnings from b-files' comments for days between 2024032 and 2024032 (0 sec, 12 rows)

TypeCommentcountpriorityfnamelocationserialtimevalueminmax
rl:2024 031 16 09 15 Checksum bad in low level command.13B03224.224TORON#22405:33:231-1
rl:2024 031 16 09 16 Motor #3: appears stuck with a reference sensor activated.13B03224.224TORON#22405:33:251-1
rl:2024 031 16 09 16 Motor #11: appears stuck with a reference sensor activated.13B03224.224TORON#22405:33:271-1
rl:2024 031 16 11 45 MAIN.C : motor initialization timed out.15B03224.224TORON#22405:33:331-1
rl:2024 032 17 52 03 Attempt to exceed min boundary13B03224.224TORON#22405:33:571-1
rl:2024 032 17 52 03 <M,1,13B03224.224TORON#22405:33:591-1
rl:2024 032 17 52 03 <M,1,15B03224.224TORON#22405:33:591-1
rl:2024 032 18 05 05 Motor #1: appears stuck with a reference sensor activated.23B03224.224TORON#22405:34:011-1
rl:2024 032 02 11 27 New value set for watermark SUPPLY.VOLTAGE.HIGH[33B03224.224TORON#22405:34:071-1
dp:Doing dispersion with internal HG.199B03224.224TORON#22411:46:551-1
pd:Going to menu299B03224.224TORON#22415:34:111-1
ze:Zenith discrepancy = 496199B03224.224TORON#22418:05:18496-1010

Measurements and tests summary.


_jday_loc_serial_skcdtedhghprssl
032TORONTO#224Azimuth drive turned OFF in op_st.,inside,menu,Must do HG now,Waiting until ZA =,Waiting until ZA = 170 now 130.8,Waiting until ZA = 170 now 132.5,Waiting until ZA = 170 now 134.2,Waiting until ZA = 170 now 135.9,Waiting until ZA = 170 now 137.6,Waiting until ZA = 170 now 139.2,Waiting until ZA = 170 now 140.7,Waiting until ZA = 170 now 142.2,Waiting until ZA = 170 now 143.7,Waiting until ZA = 170 now 145.1,Waiting until ZA = 170 now 146.4,Waiting until ZA = 170 now 147.6,Waiting until ZA = 170 now 148.8,Waiting until ZA = 170 now 149.8,Waiting until ZA = 170 now 150.7,Waiting until ZA = 170 now 151.5,Waiting until ZA = 170 now 152.1,Waiting until ZA = 170 now 152.6,Waiting until ZA = 170 now 152.9,Waiting until ZA = 170 now 153.182211889
(0 sec)

Number of days since last dome/window cleaning (0 sec, 2 rows)

serialdays
224more than a year

Missing files (0 sec, 1 rows)

Seriallast datadays ago
22420240330-1

Run/Stop results for last week. (0 sec, 1 rows)

SerialTotalFailed 0Failed darkFailed 1Failed 2Failed 3Failed 4Failed 5Failed double
2241000000000

AP results for SB Brewers. (0 sec, 1 rows)

SerialJdayt1 offt1 ont2 offt2 ont3 offt3 onHV offHV on+12V off+12V on+5V off+5V on-12V off-12V on+24V off+24V on+5V sps off+5V sps onSL A offSL A onSL V offSL V onWatts
224202403227.027.029.329.327.427.41165.21164.412.012.05.25.2-11.9-11.924.124.15.05.00.01.50.010.8316.4

Standard lamp intensity analysis (0 sec, 1 rows)

Serialminmaxfilterfixable30-day history
#224261307026373600yes