Critical warnings from b-files' comments for days between 2024022 and 2024022 (0 sec, 3 rows)

TypeCommentcountpriorityfnamelocationserialtimevalueminmax
rl:2024 022 18 29 09 Motor #3: appears stuck with a reference sensor activated.31B02224.224TORON#22405:34:451-1
rl:2024 022 18 48 53 New value set for watermark SUPPLY.VOLTAGE.HIGH[83B02224.224TORON#22405:35:061-1
skc:Azimuth drive turned OFF in op_st.12B02224.224TORON#22418:35:481-1

Instrument constant changes for the week before 2024022 (1 sec, 0 rows)

HG burned out? (AP results when HG is ON) (0 sec, 16 rows)

Hg with step corrections larger than 10 steps or multiple corrections larger than 2.5 steps (0 sec, 1 rows)

SerialYYYYJJJHG largemax correction
224202402277.0

Non-critical warnings from b-files' comments for days between 2024022 and 2024022 (0 sec, 14 rows)

TypeCommentcountpriorityfnamelocationserialtimevalueminmax
rl:2024 022 18 29 09 Checksum bad in low level command.13B02224.224TORON#22405:34:431-1
rl:2024 022 18 29 09 Motor #3: appears stuck with a reference sensor activated.13B02224.224TORON#22405:34:451-1
rl:2024 022 18 29 10 Motor #11: appears stuck with a reference sensor activated.13B02224.224TORON#22405:34:481-1
rl:2024 022 18 31 00 Motor #1: appears stuck with a reference sensor activated.13B02224.224TORON#22405:34:531-1
rl:2024 022 18 33 02 MAIN.C : motor initialization timed out.15B02224.224TORON#22405:34:551-1
rl:2024 022 18 34 09 Bad command string. Command string buffer cleared.13B02224.224TORON#22405:34:581-1
rl:2024 022 18 34 09 Bad command string. Command string buffer cleared.13B02224.224TORON#22405:34:581-1
rl:2024 022 18 34 09 <23B02224.224TORON#22405:34:591-1
rl:2024 022 18 34 15 Attempt to exceed min boundary13B02224.224TORON#22405:35:011-1
rl:2024 022 18 34 16 <M,2, 8253:M,1, 937>15B02224.224TORON#22405:35:031-1
zs:ZS intensity too low ( 144/cy), skipping.399B02224.224TORON#22412:43:591-1
ux:HOME key pressed199B02224.224TORON#22418:18:571-1
ux:UV extended scan aborted13B02224.224TORON#22418:18:581-1
pd:Going to menu199B02224.224TORON#22418:19:541-1

Measurements and tests summary.


_jday_loc_serial_skcdtedfmfzhghprssluvzs
022TORONTO#224Azimuth drive turned OFF in op_st.,ecsc,Must do HG now,Saving backup OP_ST.000,Starting schedule inside,Waiting until ZA = 170 now 129.7,Waiting until ZA = 170 now 131.5,Waiting until ZA = 170 now 133.3,Waiting until ZA = 170 now 135,Waiting until ZA = 170 now 136.7,Waiting until ZA = 170 now 138.4,Waiting until ZA = 170 now 140.1,Waiting until ZA = 170 now 141.7,Waiting until ZA = 170 now 143.3,Waiting until ZA = 170 now 144.8,Waiting until ZA = 170 now 146.3,Waiting until ZA = 170 now 147.7,Waiting until ZA = 170 now 149.1,Waiting until ZA = 170 now 150.3,Waiting until ZA = 170 now 151.5,Waiting until ZA = 170 now 152.5,Waiting until ZA = 170 now 153.5,Waiting until ZA = 170 now 154.2,Waiting until ZA = 170 now 154.9,Waiting until ZA = 170 now 155.3,Waiting until ZA = 170 now 155.6,Waiting until ZA = 170 now 155.7621322121692420
(0 sec)

Number of days since last dome/window cleaning (0 sec, 2 rows)

serialdays
224more than a year

Missing files (0 sec, 1 rows)

Seriallast datadays ago
22420240230-1

Run/Stop results for last week. (0 sec, 1 rows)

SerialTotalFailed 0Failed darkFailed 1Failed 2Failed 3Failed 4Failed 5Failed double
2241901000000

AP results for SB Brewers. (0 sec, 1 rows)

SerialJdayt1 offt1 ont2 offt2 ont3 offt3 onHV offHV on+12V off+12V on+5V off+5V on-12V off-12V on+24V off+24V on+5V sps off+5V sps onSL A offSL A onSL V offSL V onWatts
224202402219.719.622.022.018.018.01164.71163.812.012.05.25.2-12.2-12.124.124.15.05.00.01.50.010.7516.2

Standard lamp intensity analysis (0 sec, 1 rows)

Serialminmaxfilterfixable30-day history
#224234076023929300yes