Database last updated on Wed, 04 Feb 2026 08:10:52 +0000 by localhost
Critical warnings from b-files' comments for days between 2023172 and 2023172 (0 sec, 1 rows)
| Type | Comment | count | priority | fname | location | serial | time | value | min | max |
| rl: | 2023 171 05 33 35 Motor #2: appears stuck with a reference sensor activated. | 2 | 1 | | | #224 | 05:29:26 | | 1 | -1 |
Instrument constant changes for the week before 2023172 (2 sec, 0 rows)
SL burned out? (AP results when SL is ON) (0 sec, 2 rows)
HG burned out? (AP results when HG is ON) (0 sec, 5 rows)
HP with step corrections larger than 20 steps (0 sec, 1 rows)
| Serial | YYYYJJJ | HP large | max correction |
| 224 | 2023172 | 2 | 27.3 |
Non-critical warnings from b-files' comments for days between 2023172 and 2023172 (0 sec, 9 rows)
| Type | Comment | count | priority | fname | location | serial | time | value | min | max |
| ds: | DS intensity too low ( 2/cy), skipping. | 2 | 99 | | | #224 | 01:19:06 | | 1 | -1 |
| zs: | ZS intensity too low ( 21/cy), skipping. | 3 | 99 | | | #224 | 01:19:21 | | 1 | -1 |
| rl: | 2023 171 05 34 46 Bad command string. Command string buffer cleared. | 1 | 3 | | | #224 | 05:29:28 | | 1 | -1 |
| rl: | 2023 171 05 34 46 Bad command string. Command string buffer cleared. | 1 | 3 | | | #224 | 05:29:28 | | 1 | -1 |
| rl: | 2023 171 05 34 46 < | 1 | 3 | | | #224 | 05:29:30 | | 1 | -1 |
| rl: | 2023 172 16 13 20 New value set for watermark SUPPLY.VOLTAGE.HIGH[ | 1 | 3 | | | #224 | 05:29:35 | | 1 | -1 |
| sc: | HOME key pressed | 2 | 99 | | | #224 | 13:50:25 | | 1 | -1 |
| pd: | Going to menu | 1 | 99 | | | #224 | 13:51:53 | | 1 | -1 |
| si: | New SI, HC = | 1 | 99 | | | #224 | 13:56:07 | | 1 | -1 |
Measurements and tests summary.
| _jday | _loc | _serial | _skc | ds | dt | ed | hg | hp | rs | sl | uv | zs |
| 172 | TORONTO | #224 | calsc,Next schedule will be calsc (now calsc ZS= 90 ZS= 91.29799),Next schedule will be calsc (now calsc ZS= 90 ZS= 91.839) | 28 | 2 | 2 | 21 | 21 | 2 | 3 | 12 | 12 |
(0 sec)
Number of days since last dome/window cleaning (0 sec, 2 rows)
| serial | days |
| 224 | more than a year |
Missing files (0 sec, 1 rows)
| Serial | last data | days ago |
| 224 | 2023165 | 007 |
Run/Stop results for last week. (0 sec, 1 rows)
| Serial | Total | Failed 0 | Failed dark | Failed 1 | Failed 2 | Failed 3 | Failed 4 | Failed 5 | Failed double |
| 224 | 16 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
AP results for SB Brewers. (0 sec, 1 rows)
| Serial | Jday | t1 off | t1 on | t2 off | t2 on | t3 off | t3 on | HV off | HV on | +12V off | +12V on | +5V off | +5V on | -12V off | -12V on | +24V off | +24V on | +5V sps off | +5V sps on | SL A off | SL A on | SL V off | SL V on | Watts |
| 224 | 2023172 | 23.0 | 23.1 | 23.9 | 23.9 | 22.9 | 22.9 | 1168.7 | 1169.2 | 12.0 | 12.0 | 5.2 | 5.2 | -11.9 | -11.9 | 24.1 | 24.1 | 5.0 | 5.0 | 0.0 | 1.5 | 0.0 | 10.60 | 16.1 |
Standard lamp intensity analysis (0 sec, 1 rows)
| Serial | min | max | filter | fixable | 30-day history |
| #224 | 2349280 | 2355650 | 0 | yes |