| Type | Comment | count | priority | fname | location | serial | time | value | min | max |
|---|---|---|---|---|---|---|---|---|---|---|
| rl: | 2023 124 05 37 08 New value set for watermark SUPPLY.VOLTAGE.HIGH[ | 95 | 3 | #224 | 05:23:26 | 1 | -1 | |||
| rl: | 2023 124 05 39 05 Motor #2: appears stuck with a reference sensor activated. | 6 | 1 | #224 | 05:23:55 | 1 | -1 |
| Serial | YYYYJJJ | HG large | max correction |
|---|---|---|---|
| 224 | 2023125 | 2 | 3.2 |
| Type | Comment | count | priority | fname | location | serial | time | value | min | max |
|---|---|---|---|---|---|---|---|---|---|---|
| zs: | ZS intensity too low ( 2/cy), skipping. | 2 | 99 | #224 | 00:56:39 | 1 | -1 | |||
| rl: | Log item overwritten by later entry. | 1 | 3 | #224 | 05:23:24 | 1 | -1 | |||
| rl: | 2023 124 05 38 17 Bad command string. Command string buffer cleared. | 1 | 3 | #224 | 05:23:51 | 1 | -1 | |||
| rl: | 2023 124 05 38 17 Bad command string. Command string buffer cleared. | 1 | 3 | #224 | 05:23:51 | 1 | -1 | |||
| rl: | 2023 124 05 38 17 <' | 1 | 3 | #224 | 05:23:53 | 1 | -1 | |||
| rl: | 2023 125 17 56 02 Motor #1: appears stuck with a reference sensor activated. | 2 | 3 | #224 | 05:26:22 | 1 | -1 | |||
| dp: | Doing dispersion with internal HG. | 1 | 99 | #224 | 09:53:36 | 1 | -1 | |||
| sc: | SC intensity too low ( 48/cy), skipping. | 3 | 3 | #224 | 11:33:45 | 1 | -1 | |||
| ux: | HOME key pressed | 2 | 99 | #224 | 17:06:15 | 1 | -1 | |||
| ux: | UV extended scan aborted | 1 | 3 | #224 | 17:06:17 | 1 | -1 | |||
| pd: | Going to menu | 2 | 99 | #224 | 17:07:55 | 1 | -1 | |||
| si: | New SI, HC = | 4 | 99 | #224 | 17:16:12 | 1 | -1 | |||
| ds: | DS intensity too high ( 274017/cy) quitting. | 1 | 99 | #224 | 21:21:56 | 1 | -1 |
| _jday | _loc | _serial | _skc | ds | dt | ed | fm | fz | hg | hp | rs | sl | uv | zs |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 125 | TORONTO | #224 | calsc,Next schedule will be calsc (now calsc ZS= 90 ZS= 90.969),Next schedule will be calsc (now calsc ZS= 90 ZS= 91.588) | 54 | 2 | 2 | 11 | 2 | 26 | 25 | 2 | 6 | 13 | 26 |
| serial | days |
|---|---|
| 224 | more than a year |
| Serial | last data | days ago |
|---|---|---|
| 224 | 2023124 | 001 |
| Serial | Total | Failed 0 | Failed dark | Failed 1 | Failed 2 | Failed 3 | Failed 4 | Failed 5 | Failed double |
|---|---|---|---|---|---|---|---|---|---|
| 224 | 16 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| Serial | Jday | t1 off | t1 on | t2 off | t2 on | t3 off | t3 on | HV off | HV on | +12V off | +12V on | +5V off | +5V on | -12V off | -12V on | +24V off | +24V on | +5V sps off | +5V sps on | SL A off | SL A on | SL V off | SL V on | Watts |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 224 | 2023125 | 18.2 | 18.2 | 19.6 | 19.6 | 16.2 | 16.2 | 1168.0 | 1168.3 | 14.4 | 14.4 | 5.7 | 5.7 | -12.9 | -12.9 | 29.9 | 29.9 | 5.7 | 5.7 | 0.0 | 1.5 | 0.0 | 10.55 | 16.0 |
| Serial | min | max | filter | fixable | 30-day history |
|---|---|---|---|---|---|
| #224 | 2959750 | 2961380 | 0 | yes |