| Type | Comment | count | priority | fname | location | serial | time | value | min | max |
|---|---|---|---|---|---|---|---|---|---|---|
| rl: | 2021 160 16 00 47 Motor #3: appears stuck with a reference sensor activated. | 2 | 1 | B16021.224 | TORON | #224 | 05:20:28 | 1 | -1 | |
| rl: | 2021 160 16 19 19 <M,6,242> | 13 | 3 | B16021.224 | TORON | #224 | 05:20:41 | 1 | -1 | |
| rl: | 2021 160 16 19 19 <M,6,242> | 13 | 5 | B16021.224 | TORON | #224 | 05:20:41 | 1 | -1 | |
| fr: | 11000 steps - QUIT - Micrometer #1 reference not found | 1 | 1 | B16021.224 | TORON | #224 | 06:29:06 | 1 | -1 |
| Serial | YYYYJJJ | HG large | max correction |
|---|---|---|---|
| 224 | 2021160 | 17 | 8.8 |
| Type | Comment | count | priority | fname | location | serial | time | value | min | max |
|---|---|---|---|---|---|---|---|---|---|---|
| rl: | 2021 160 16 00 47 Reset Tepid -> Tepid from 2021 160 15 44 25 until 2021 160 16 00 41 . Counts: 1,0 | 1 | 3 | B16021.224 | TORON | #224 | 05:20:25 | 1 | -1 | |
| rl: | 2021 160 16 00 47 Motor #3: appears stuck with a reference sensor activated. | 1 | 3 | B16021.224 | TORON | #224 | 05:20:28 | 1 | -1 | |
| rl: | 2021 160 16 00 48 Motor #11: appears stuck with a reference sensor activated. | 1 | 3 | B16021.224 | TORON | #224 | 05:20:31 | 1 | -1 | |
| rl: | 2021 160 16 02 56 MAIN.C : motor initialization timed out. | 1 | 5 | B16021.224 | TORON | #224 | 05:20:33 | 1 | -1 | |
| rl: | 2021 160 16 43 07 New value set for watermark LOOP.RUN.TIME: 700.000000 millisec. | 3 | 3 | B16021.224 | TORON | #224 | 05:21:03 | 1 | -1 | |
| rl: | 2021 160 16 43 07 New value set for watermark LOOP.RUN.TIME: 700.000000 millisec. | 3 | 3 | B16021.224 | TORON | #224 | 05:21:03 | 1 | -1 | |
| dp: | Doing dispersion with internal HG. | 1 | 99 | B16021.224 | TORON | #224 | 08:29:58 | 1 | -1 | |
| sl: | HOME key pressed | 3 | 99 | B16021.224 | TORON | #224 | 11:04:30 | 1 | -1 | |
| sl: | Going to menu | 2 | 99 | B16021.224 | TORON | #224 | 11:04:34 | 1 | -1 | |
| ze: | Zenith discrepancy = 898 | 2 | 99 | B16021.224 | TORON | #224 | 11:36:25 | 898 | -10 | 10 |
| dsp: | Doing dispersion test with Cd (UV port) | 2 | 99 | B16021.224 | TORON | #224 | 12:33:33 | 1 | -1 | |
| op: | Illegal command (op) in schedule , ignoring | 1 | 99 | B16021.224 | TORON | #224 | 15:28:41 | 1 | -1 |
| _jday | _loc | _serial | _skc | dt | ed | hg | hp | rs | sl | uv |
|---|---|---|---|---|---|---|---|---|---|---|
| 160 | TORONTO | #224 | inside,Waiting until ZA = 170 now 113,Waiting until ZA = 170 now 113.1,Waiting until ZA = -100 now -100.5,Waiting until ZA = -100 now -101.7,Waiting until ZA = -100 now -102.9,Waiting until ZA = -100 now -104,Waiting until ZA = -100 now -105.1,Waiting until ZA = -100 now -106.1,Waiting until ZA = -80 now -80.3,Waiting until ZA = -85 now -85.4,Waiting until ZA = -85 now -87,Waiting until ZA = -85 now -88.5,Waiting until ZA = -85 now -89.8,Waiting until ZA = -85 now -91.8,Waiting until ZA = -85 now -93.3,Waiting until ZA = -85 now -94.7 | 12 | 2 | 44 | 43 | 12 | 13 | 1 |
| serial | days |
|---|---|
| 224 | more than a year |
| Serial | last data | days ago |
|---|---|---|
| 224 | 2021161 | 0-1 |
| Serial | Total | Failed 0 | Failed dark | Failed 1 | Failed 2 | Failed 3 | Failed 4 | Failed 5 | Failed double |
|---|---|---|---|---|---|---|---|---|---|
| 224 | 89 | 0 | 27 | 0 | 0 | 0 | 0 | 0 | 0 |
| Serial | Jday | t1 off | t1 on | t2 off | t2 on | t3 off | t3 on | HV off | HV on | +12V off | +12V on | +5V off | +5V on | -12V off | -12V on | +24V off | +24V on | +5V sps off | +5V sps on | SL A off | SL A on | SL V off | SL V on | Watts |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 224 | 2021160 | 31.0 | 31.0 | 31.7 | 31.7 | 30.2 | 30.1 | 1214.2 | 1214.1 | 12.0 | 12.0 | 5.0 | 5.0 | -11.4 | -11.5 | 24.2 | 24.2 | 5.0 | 5.0 | 0.0 | 1.5 | 0.0 | 10.06 | 14.9 |
| Serial | min | max | filter | fixable | 30-day history |
|---|---|---|---|---|---|
| #224 | 2951320 | 2981940 | 0 | yes |