Database last updated on Sun, 13 Sep 2026 06:11:03 +0000 by localhost

Critical warnings from b-files' comments for days between 2018346 and 2018346 (0 sec, 2 rows)

TypeCommentcountpriorityfnamelocationserialtimevalueminmax
rl:2018 345 05 28 11 Motor #2: appears stuck with a reference sensor activated.21B34618.223TORON#22305:20:361-1
rl:2018 345 06 35 01 PMT counter failure11B34618.223TORON#22305:20:451-1

Instrument constant changes for the week before 2018346 (3 sec, 0 rows)

SL burned out? (AP results when SL is ON) (0 sec, 5 rows)

SerialYYYYJJJSL CurrentSL Voltage
2232018342-12.1824.37
2232018343-12.1724.4
2232018344-12.1824.37
2232018345-12.1724.37
2232018346-12.1724.37

HG burned out? (AP results when HG is ON) (0 sec, 20 rows)

Hg with step corrections larger than 10 steps or multiple corrections larger than 2.5 steps (0 sec, 1 rows)

SerialYYYYJJJHG largemax correction
2232018346116.3

Non-critical warnings from b-files' comments for days between 2018346 and 2018346 (0 sec, 4 rows)

TypeCommentcountpriorityfnamelocationserialtimevalueminmax
rl:2018 345 05 25 57 Reset Warm -> Tepid from 2018 345 05 25 51 until 2018 345 05 25 52 . Counts: 1,013B34618.223TORON#22305:20:341-1
rl:2018 345 05 49 59 New value set for watermark LOOP.RUN.TIME: 653.999996 millisec.33B34618.223TORON#22305:20:411-1
rl:2018 345 05 49 59 New value set for watermark LOOP.RUN.TIME: 653.999996 millisec.33B34618.223TORON#22305:20:411-1
cfg_out:Illegal command (cfg199B34618.223TORON#22305:20:531-1

Measurements and tests summary.


_jday_loc_serial_skcdtedfzhghprssluvzs
346TORONTO#223calsc2181514281563
(1 sec)

New operators? (0 sec, 147 rows)

OperatorSerial
RS223
MLB223

Relative and absolute humidity for day 2018346 (1 sec, 1 rows)

SerialRH, %AH, g/m37-day RH historyDes-nt replcd days ago
22312.91.9