Database last updated on Mon, 14 Sep 2026 11:11:02 +0000 by localhost
Critical warnings from b-files' comments for days between 2018120 and 2018120 (0 sec, 2 rows)
| Type | Comment | count | priority | fname | location | serial | time | value | min | max |
| sc: | SC intensity too low ( 8/cy), skipping. | 17 | 3 | B12018.223 | Delft | #223 | 06:50:02 | | 1 | -1 |
| rl: | 2018 120 00 24 14 Motor #2: appears stuck with a reference sensor activated. | 2 | 1 | B12018.223 | Delft | #223 | 23:39:59 | | 1 | -1 |
Instrument constant changes for the week before 2018120 (4 sec, 0 rows)
SL burned out? (AP results when SL is ON) (0 sec, 4 rows)
HG burned out? (AP results when HG is ON) (0 sec, 10 rows)
Hg with step corrections larger than 10 steps or multiple corrections larger than 2.5 steps (0 sec, 1 rows)
| Serial | YYYYJJJ | HG large | max correction |
| 223 | 2018120 | 2 | 6.3 |
HP with step corrections larger than 20 steps (0 sec, 1 rows)
| Serial | YYYYJJJ | HP large | max correction |
| 223 | 2018120 | 6 | 46.0 |
Non-critical warnings from b-files' comments for days between 2018120 and 2018120 (0 sec, 3 rows)
| Type | Comment | count | priority | fname | location | serial | time | value | min | max |
| td: | Time correction 5.1 seconds | 1 | 3 | B12018.223 | Delft | #223 | 00:32:47 | 5.1 | -3 | 3 |
| rl: | 2018 120 00 22 43 MOTOR.MAX.JERK: Symbol not found. | 2 | 3 | B12018.223 | Delft | #223 | 23:39:57 | | 1 | -1 |
| chk_cfg: | MOTOR.MAX.JERK[10]=(symbol not found) | 2 | 3 | B12018.223 | Delft | #223 | 23:40:08 | | 1 | -1 |
Measurements and tests summary.
| _jday | _loc | _serial | _skc | ds | dt | ed | hg | hp | rs | sl | uv |
| 120 | Delft | #223 | dsmk3ec | 1 | 12 | 1 | 41 | 49 | 12 | 55 | 10 |
(0 sec)
New operators? (0 sec, 8 rows)
Relative and absolute humidity for day 2018120 (2 sec, 1 rows)
| Serial | RH, % | AH, g/m3 | 7-day RH history | Des-nt replcd days ago |
| 223 | 26.7 | 3.2 |