Database last updated on Mon, 14 Sep 2026 10:11:03 +0000 by localhost
Critical warnings from b-files' comments for days between 2018105 and 2018105 (0 sec, 1 rows)
| Type | Comment | count | priority | fname | location | serial | time | value | min | max |
| rl: | 2018 104 23 51 16 Motor #2: appears stuck with a reference sensor activated. | 3 | 1 | B10518.223 | Delft | #223 | 23:42:48 | | 1 | -1 |
Instrument constant changes for the week before 2018105 (2 sec, 0 rows)
HG burned out? (AP results when HG is ON) (0 sec, 9 rows)
Non-critical warnings from b-files' comments for days between 2018105 and 2018105 (0 sec, 3 rows)
| Type | Comment | count | priority | fname | location | serial | time | value | min | max |
| ds: | Suppressed oscillation of filter wheel. | 1 | 5 | B10518.223 | Delft | #223 | 12:17:25 | | 1 | -1 |
| rl: | 2018 104 23 50 02 MOTOR.MAX.JERK: Symbol not found. | 2 | 3 | B10518.223 | Delft | #223 | 23:42:46 | | 1 | -1 |
| chk_cfg: | MOTOR.MAX.JERK[10]=(symbol not found) | 2 | 3 | B10518.223 | Delft | #223 | 23:42:59 | | 1 | -1 |
Measurements and tests summary.
| _jday | _loc | _serial | _skc | ds | dt | ed | hg | hp | rs | sl | zs |
| 105 | Delft | #223 | dsmk3p | 53 | 3 | 1 | 47 | 46 | 3 | 37 | 1 |
(0 sec)
New operators? (0 sec, 131 rows)
Relative and absolute humidity for day 2018105 (2 sec, 1 rows)
| Serial | RH, % | AH, g/m3 | 7-day RH history | Des-nt replcd days ago |
| 223 | 25.1 | 5.2 |