Database last updated on Sun, 15 Mar 2026 13:40:41 +0000 by localhost

Critical warnings from b-files' comments for days between 2026030 and 2026030 (0 sec, 1 rows)

TypeCommentcountpriorityfnamelocationserialtimevalueminmax
rl:2026 031 01 17 48 Motor #3: appears stuck with a reference sensor activated.21B03026.206SATUR#20608:29:071-1

Instrument constant changes for the week before 2026030 (2 sec, 0 rows)

SL burned out? (AP results when SL is ON) (0 sec, 7 rows)

Hg with step corrections larger than 10 steps or multiple corrections larger than 2.5 steps (0 sec, 1 rows)

SerialYYYYJJJHG largemax correction
2062026030242.0

Non-critical warnings from b-files' comments for days between 2026030 and 2026030 (0 sec, 6 rows)

TypeCommentcountpriorityfnamelocationserialtimevalueminmax
re:Zenith discrepancy = 11199B03026.206SATUR#20601:20:2211-1010
rl:2026 031 01 17 47 Reset No -> Tepid from 2026 030 20 10 17 until 2041 359 18 49 26 . Counts: 1,013B03026.206SATUR#20608:29:031-1
rl:2026 031 01 17 48 Checksum bad in low level command.13B03026.206SATUR#20608:29:051-1
rl:2026 031 01 17 48 Motor #3: appears stuck with a reference sensor activated.13B03026.206SATUR#20608:29:071-1
rl:2026 031 01 17 48 Motor #11: appears stuck with a reference sensor activated.13B03026.206SATUR#20608:29:101-1
rl:2026 031 01 19 19 Reset Warm -> Warm from 2026 031 01 19 16 until 2026 031 01 19 17 . Counts: 0,113B03026.206SATUR#20608:29:131-1

Measurements and tests summary.


_jday_loc_serial_skcdtedfmfzhghprsslzs
030SATURNA#206ecsc,Next schedule will be ecsc (now ecsc ZS= 93 ZS= 93.024)1348114151535
(0 sec)

Relative and absolute humidity for day 2026030 (2 sec, 1 rows)

SerialRH, %AH, g/m37-day RH historyDes-nt replcd days ago
20613.91.5