Database last updated on Fri, 30 Jan 2026 23:40:49 +0000 by localhost

Critical warnings from b-files' comments for days between 2024253 and 2024253 (0 sec, 5 rows)

TypeCommentcountpriorityfnamelocationserialtimevalueminmax
hg:HG failed11B25324.206SATUR#20602:32:28failed1-1
rl:2024 252 14 55 31 Motor #11: appears stuck with a reference sensor activated.1471B25324.206SATUR#20608:18:111-1
rl:2024 252 14 55 31 Motor #11: appears stuck with a reference sensor activated.1473B25324.206SATUR#20608:18:111-1
hg:Lamp not on... hg test terminated F1= 2281 F4= 130211B25324.206SATUR#20615:52:471-1
hg:Lamp not detected f1= 2281 f4= 130211B25324.206SATUR#20615:52:481-1

Instrument constant changes for the week before 2024253 (1 sec, 0 rows)

Hg with step corrections larger than 10 steps or multiple corrections larger than 2.5 steps (0 sec, 1 rows)

SerialYYYYJJJHG largemax correction
2062024253105.6

Non-critical warnings from b-files' comments for days between 2024253 and 2024253 (0 sec, 4 rows)

TypeCommentcountpriorityfnamelocationserialtimevalueminmax
rl:2024 252 14 55 30 Reset Warm -> Tepid from 2024 252 14 55 24 until 2024 252 14 55 24 . Counts: 1,023B25324.206SATUR#20608:18:081-1
rl:2024 252 14 57 39 MAIN.C : motor initialization timed out.35B25324.206SATUR#20608:23:331-1
rl:2024 252 15 41 34 Reset No -> Warm from 2024 252 15 41 31 until 2024 252 15 41 31 . Counts: 0,113B25324.206SATUR#20608:23:391-1
re:Azimuth discrepancy = -402399B25324.206SATUR#20614:58:01-402-3030

Measurements and tests summary.


_jday_loc_serial_skcdsdtedfzhghpsluvzs
253SATURNA#206ecsc,Next schedule will be ecsc (now ecsc ZS= 93 ZS= 94.25)22121281742156
(1 sec)

Relative and absolute humidity for day 2024253 (1 sec, 1 rows)

SerialRH, %AH, g/m37-day RH historyDes-nt replcd days ago
2065.11.2