| Type | Comment | count | priority | fname | location | serial | time | value | min | max |
| rl: | 2025 193 21 17 39 Reset No -> Tepid from 2025 193 21 17 25 until 2016 193 21 17 34 . Counts: 1,0 | 1 | 3 | B19425.205 | RESOL | #205 | 00:21:16 | | 1 | -1 |
| rl: | 2025 193 21 17 39 Checksum bad in low level command. | 1 | 3 | B19425.205 | RESOL | #205 | 00:21:18 | | 1 | -1 |
| rl: | 2025 193 21 17 40 Motor #3: appears stuck with a reference sensor activated. | 1 | 3 | B19425.205 | RESOL | #205 | 00:21:20 | | 1 | -1 |
| rl: | 2025 193 21 17 40 Motor #11: appears stuck with a reference sensor activated. | 1 | 3 | B19425.205 | RESOL | #205 | 00:21:22 | | 1 | -1 |
| rl: | 2025 193 21 18 25 Reset Warm -> Warm from 2025 193 21 18 22 until 2025 193 21 18 22 . Counts: 1,1 | 1 | 3 | B19425.205 | RESOL | #205 | 00:21:26 | | 1 | -1 |
| rl: | 2025 193 21 18 26 Motor #10: appears stuck with a reference sensor activated. | 1 | 3 | B19425.205 | RESOL | #205 | 00:21:28 | | 1 | -1 |
| rl: | 2025 193 21 20 35 MAIN.C : motor initialization timed out. | 1 | 5 | B19425.205 | RESOL | #205 | 00:21:30 | | 1 | -1 |
| rl: | 2025 192 18 34 20 Reset No -> Tepid from 2025 192 18 15 16 until 2016 192 18 34 14 . Counts: 1,0 | 1 | 3 | B19425.205 | RESOL | #205 | 12:42:21 | | 1 | -1 |
| rl: | 2025 192 18 34 20 Checksum bad in low level command. | 1 | 3 | B19425.205 | RESOL | #205 | 12:42:23 | | 1 | -1 |
| rl: | 2025 192 18 34 20 Motor #3: appears stuck with a reference sensor activated. | 1 | 3 | B19425.205 | RESOL | #205 | 12:42:25 | | 1 | -1 |
| rl: | 2025 192 18 34 21 Motor #11: appears stuck with a reference sensor activated. | 1 | 3 | B19425.205 | RESOL | #205 | 12:42:28 | | 1 | -1 |
| rl: | 2025 192 18 34 56 Reset Warm -> Warm from 2025 192 18 34 53 until 2025 192 18 34 54 . Counts: 1,1 | 1 | 3 | B19425.205 | RESOL | #205 | 12:42:31 | | 1 | -1 |
| rl: | 2025 192 18 37 06 MAIN.C : motor initialization timed out. | 1 | 5 | B19425.205 | RESOL | #205 | 12:42:33 | | 1 | -1 |
| rl: | 2025 192 22 32 43 Motor #10: appears stuck with a reference sensor activated. | 2 | 3 | B19425.205 | RESOL | #205 | 12:43:06 | | 1 | -1 |
| rl: | 2025 192 22 33 33 Motor #9: appears stuck with a reference sensor activated. | 1 | 3 | B19425.205 | RESOL | #205 | 12:43:10 | | 1 | -1 |
| rl: | 2025 193 00 30 45 Attempt to exceed min boundary | 4 | 3 | B19425.205 | RESOL | #205 | 12:43:26 | | 1 | -1 |
| rl: | 2025 193 00 30 45 <M,10,-1736> | 4 | 5 | B19425.205 | RESOL | #205 | 12:43:28 | | 1 | -1 |
| rl: | 2025 193 12 48 57 Bad command string. Command string buffer cleared. | 1 | 3 | B19425.205 | RESOL | #205 | 14:25:43 | | 1 | -1 |
| rl: | 2025 193 12 48 57 Bad command string. Command string buffer cleared. | 1 | 3 | B19425.205 | RESOL | #205 | 14:25:43 | | 1 | -1 |
| ew: | Command file ew not found --- continuing | 1 | 99 | B19425.205 | RESOL | #205 | 20:57:08 | continuing | 1 | -1 |