Critical warnings from b-files' comments for days between 2023309 and 2023309 (0 sec, 2 rows)
| Type | Comment | count | priority | fname | location | serial | time | value | min | max |
| rl: | 2023 309 04 10 59 Motor #2: appears stuck with a reference sensor activated. | 1 | 1 | | | #204 | 03:55:19 | | 1 | -1 |
| rl: | 2023 309 04 54 43 PMT counter failure | 1 | 1 | | | #204 | 03:55:29 | | 1 | -1 |
Instrument constant changes for the week before 2023309 (1 sec, 0 rows)
HG burned out? (AP results when HG is ON) (0 sec, 16 rows)
Non-critical warnings from b-files' comments for days between 2023309 and 2023309 (0 sec, 6 rows)
| Type | Comment | count | priority | fname | location | serial | time | value | min | max |
| rl: | 2023 309 04 09 51 Bad command string. Command string buffer cleared. | 1 | 3 | | | #204 | 03:55:15 | | 1 | -1 |
| rl: | 2023 309 04 09 51 Bad command string. Command string buffer cleared. | 1 | 3 | | | #204 | 03:55:15 | | 1 | -1 |
| rl: | 2023 309 04 09 51 < | 1 | 3 | | | #204 | 03:55:17 | | 1 | -1 |
| rl: | 2023 309 04 29 30 New value set for watermark LOOP.RUN.TIME: 674.000025 millisec. | 3 | 3 | | | #204 | 03:55:22 | | 1 | -1 |
| rl: | 2023 309 04 29 30 New value set for watermark LOOP.RUN.TIME: 674.000025 millisec. | 3 | 3 | | | #204 | 03:55:22 | | 1 | -1 |
| zs: | ZS intensity too low ( 148/cy), skipping. | 4 | 99 | | | #204 | 11:11:16 | | 1 | -1 |
Measurements and tests summary.
| _jday | _loc | _serial | _skc | aode | ds | dt | ed | fm | fz | hg | hp | rs | sl | uv | zs |
| 309 | GOOSE BAY | #204 | ecsc,Next schedule will be ecsc (now ecsc ZS= 93 ZS= 93.08) | 18 | 18 | 2 | 2 | 26 | 2 | 17 | 16 | 2 | 6 | 42 | 18 |
(0 sec)
Dead time (0 sec)
Nothing to report.
Standard lamp R6 (2 sec)
Nothing to report.
Standard lamp R5 (1 sec)
Nothing to report.
Number of days since last dome/window cleaning (0 sec, 2 rows)
| serial | days |
| 204 | more than a year |
Missing files (0 sec, 1 rows)
| Serial | last data | days ago |
| 204 | 2023308 | 001 |
Run/Stop results for last week. (0 sec, 1 rows)
| Serial | Total | Failed 0 | Failed dark | Failed 1 | Failed 2 | Failed 3 | Failed 4 | Failed 5 | Failed double |
| 204 | 4 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
AP results for SB Brewers. (0 sec, 1 rows)
| Serial | Jday | t1 off | t1 on | t2 off | t2 on | t3 off | t3 on | HV off | HV on | +12V off | +12V on | +5V off | +5V on | -12V off | -12V on | +24V off | +24V on | +5V sps off | +5V sps on | SL A off | SL A on | SL V off | SL V on | Watts |
| 204 | 2023309 | 17.1 | 17.1 | 18.2 | 18.3 | 12.9 | 12.9 | 1490.2 | 1490.6 | 12.2 | 12.2 | 5.1 | 5.1 | -12.0 | -12.0 | 24.2 | 24.2 | 5.0 | 5.0 | 0.0 | 1.5 | 0.0 | 10.50 | 16.0 |
Standard lamp intensity analysis (0 sec, 1 rows)
| Serial | min | max | filter | fixable | 30-day history |
| #204 | 2902850 | 2902930 | 0 | yes |