Database last updated on Tue, 08 Sep 2026 14:43:04 +0000 by localhost

Critical warnings from b-files' comments for days between 2020213 and 2020213 (0 sec, 2 rows)

TypeCommentcountpriorityfnamelocationserialtimevalueminmax
rl:2020 213 09 03 03 Motor #3: appears stuck with a reference sensor activated.21B21320.204GOOSE#20404:15:561-1
ux:Brewer failed to respond 5 times11B21320.204GOOSE#20411:19:161-1

Instrument constant changes for the week before 2020213 (2 sec, 0 rows)

Hg with step corrections larger than 10 steps or multiple corrections larger than 2.5 steps (0 sec, 1 rows)

SerialYYYYJJJHG largemax correction
204202021349.5

Non-critical warnings from b-files' comments for days between 2020213 and 2020213 (0 sec, 7 rows)

TypeCommentcountpriorityfnamelocationserialtimevalueminmax
rl:2020 213 09 03 02 Reset No -> Tepid from 2020 213 09 02 53 until 2028 213 09 02 57 . Counts: 1,023B21320.204GOOSE#20404:15:521-1
rl:2020 213 09 03 02 Checksum bad in low level command.13B21320.204GOOSE#20404:15:531-1
rl:2020 213 09 03 03 Motor #3: appears stuck with a reference sensor activated.13B21320.204GOOSE#20404:15:561-1
rl:2020 213 09 03 03 Motor #11: appears stuck with a reference sensor activated.13B21320.204GOOSE#20404:15:581-1
rl:2020 213 12 04 24 Reset Warm -> Warm from 2020 213 12 04 21 until 2020 213 12 04 22 . Counts: 0,113B21320.204GOOSE#20404:16:021-1
ds:DS intensity too high ( 216347/cy) quitting.199B21320.204GOOSE#20417:13:211-1
ds:Suppressed oscillation of filter wheel.25B21320.204GOOSE#20417:43:031-1

Measurements and tests summary.


_jday_loc_serial_skcaodedsdtedhghprssluvzs
213GOOSE BAY#204ecsc5556212116255133
(0 sec)

Relative and absolute humidity for day 2020213 (2 sec, 1 rows)

SerialRH, %AH, g/m37-day RH historyDes-nt replcd days ago
2044.31.0