Database last updated on Mon, 26 Jan 2026 11:40:48 +0000 by localhost

Critical warnings from b-files' comments for days between 2025161 and 2025161 (0 sec, 3 rows)

TypeCommentcountpriorityfnamelocationserialtimevalueminmax
rl:2025 160 07 54 05 Motor #2: appears stuck with a reference sensor activated.31B16125.195STONY#19507:41:541-1
rl:2025 160 08 20 34 New value set for watermark LOOP.RUN.TIME: 683.000040 millisec.73B16125.195STONY#19507:41:591-1
rl:2025 160 08 20 34 New value set for watermark LOOP.RUN.TIME: 683.000040 millisec.73B16125.195STONY#19507:41:591-1

Instrument constant changes for the week before 2025161 (2 sec, 0 rows)

HP with step corrections larger than 20 steps (0 sec, 1 rows)

SerialYYYYJJJHP largemax correction
1952025161150.0

Non-critical warnings from b-files' comments for days between 2025161 and 2025161 (1 sec, 8 rows)

TypeCommentcountpriorityfnamelocationserialtimevalueminmax
rl:2025 160 07 52 55 Reset Warm -> Tepid from 2025 160 07 52 49 until 2025 160 07 52 49 . Counts: 1,013B16125.195STONY#19507:41:511-1
rl:2025 160 08 20 34 New value set for watermark LOOP.RUN.TIME: 683.000040 millisec.13B16125.195STONY#19507:41:591-1
rl:2025 160 08 20 34 New value set for watermark LOOP.RUN.TIME: 683.000040 millisec.13B16125.195STONY#19507:41:591-1
rl:2025 161 09 06 29 Attempt to exceed min boundary13B16125.195STONY#19507:42:041-1
rl:2025 161 09 06 29 <M,9,-1740>13B16125.195STONY#19507:42:061-1
rl:2025 161 09 06 29 <M,9,-1740>15B16125.195STONY#19507:42:061-1
fz:Suppressed oscillation of filter wheel.15B16125.195STONY#19513:24:131-1
ds:DS intensity too high ( 286828/cy) quitting.299B16125.195STONY#19521:29:051-1

Measurements and tests summary.


_jday_loc_serial_skcaodedsdtedfzhghprsslzs
161STONY PLAIN#195ecnouv,Next schedule will be ecnouv (now ecnouv ZS= 93 ZS= 93.01)149149221823242848
(1 sec)

Relative and absolute humidity for day 2025161 (1 sec, 1 rows)

SerialRH, %AH, g/m37-day RH historyDes-nt replcd days ago
1952.50.7