Database last updated on Mon, 02 Feb 2026 22:10:53 +0000 by localhost

Critical warnings from b-files' comments for days between 2022329 and 2022329 (0 sec, 2 rows)

TypeCommentcountpriorityfnamelocationserialtimevalueminmax
rl:2022 329 07 50 32 Motor #2: appears stuck with a reference sensor activated.21B32922.195STONY#19507:35:381-1
rl:2022 329 07 50 48 Command not accepted while another in progress.11B32922.195STONY#19507:35:401-1

Instrument constant changes for the week before 2022329 (2 sec, 0 rows)

Non-critical warnings from b-files' comments for days between 2022329 and 2022329 (1 sec, 7 rows)

TypeCommentcountpriorityfnamelocationserialtimevalueminmax
rl:2022 329 07 49 22 Reset Warm -> Tepid from 2022 329 07 49 16 until 2022 329 07 49 16 . Counts: 1,013B32922.195STONY#19507:35:351-1
rl:2022 329 07 51 45 Bad command string. Command string buffer cleared.13B32922.195STONY#19507:35:431-1
rl:2022 329 07 51 45 Bad command string. Command string buffer cleared.13B32922.195STONY#19507:35:431-1
rl:2022 329 07 51 45 <13B32922.195STONY#19507:35:451-1
rl:2022 329 08 25 15 New value set for watermark LOOP.RUN.TIME: 653.999996 millisec.23B32922.195STONY#19507:35:501-1
rl:2022 329 08 25 15 New value set for watermark LOOP.RUN.TIME: 653.999996 millisec.23B32922.195STONY#19507:35:501-1
zs:ZS intensity too low ( 135/cy), skipping.499B32922.195STONY#19515:14:571-1

Measurements and tests summary.


_jday_loc_serial_skcdtedfzhghprssluvzs
329STONY PLAIN#195ECSC,Next schedule will be ecsc (now ECSC ZS= 93 ZS= 93.009)1211415173829
(1 sec)

Relative and absolute humidity for day 2022329 (1 sec, 1 rows)

SerialRH, %AH, g/m37-day RH historyDes-nt replcd days ago
1956.50.9