Database last updated on Sun, 01 Feb 2026 14:10:54 +0000 by localhost

Critical warnings from b-files' comments for days between 2023332 and 2023332 (0 sec, 2 rows)

TypeCommentcountpriorityfnamelocationserialtimevalueminmax
rl:2023 332 15 19 27 Motor #3: appears stuck with a reference sensor activated.21B33223.194Toron#19405:09:491-1
rl:2023 332 15 20 39 New value set for watermark SUPPLY.VOLTAGE.HIGH[HV]: 1282.696838 Volts.333B33223.194Toron#19405:10:001-1

Instrument constant changes for the week before 2023332 (4 sec, 0 rows)

SL burned out? (AP results when SL is ON) (0 sec, 2 rows)

SerialYYYYJJJSL CurrentSL Voltage
1942023327010.05
19420233321.4510.14

HG burned out? (AP results when HG is ON) (0 sec, 5 rows)

SerialYYYYJJJHG CurrentHG Voltage
19420233250.1913.78
19420233280.1813.77
19420233320.3213.81
19420233320.1813.81
19420233320.1813.84

Non-critical warnings from b-files' comments for days between 2023332 and 2023332 (0 sec, 6 rows)

TypeCommentcountpriorityfnamelocationserialtimevalueminmax
rl:2023 332 15 19 27 Checksum bad in low level command.13B33223.194Toron#19405:09:471-1
rl:2023 332 15 19 27 Motor #3: appears stuck with a reference sensor activated.13B33223.194Toron#19405:09:491-1
rl:2023 332 15 19 27 Motor #11: appears stuck with a reference sensor activated.13B33223.194Toron#19405:09:511-1
si:New SI, HC = 11, NC = 720 Old = 3 , 690199B33223.194Toron#19415:48:201-1
w3:HOME key pressed199B33223.194Toron#19418:06:461-1
pd:Going to menu199B33223.194Toron#19418:06:471-1

Measurements and tests summary.


_jday_loc_serial_skcaodedsdtedfmhghprssluvzs
332Toronto#194menu,Must do HG now,Next schedule will be ecsc (now ecsc ZS= 93 ZS= 94.033),Saving backup OP_ST.000,Starting schedule ecsc442221161524174
(0 sec)

Relative and absolute humidity for day 2023332 (2 sec, 1 rows)

SerialRH, %AH, g/m37-day RH historyDes-nt replcd days ago
19410.71.7