Database last updated on Sun, 01 Feb 2026 17:40:48 +0000 by localhost
Critical warnings from b-files' comments for days between 2023296 and 2023296 (1 sec, 2 rows)
| Type | Comment | count | priority | fname | location | serial | time | value | min | max |
| rl: | 2023 295 05 38 37 New value set for watermark SUPPLY.VOLTAGE.HIGH[ | 21 | 3 | | | #194 | 05:18:37 | | 1 | -1 |
| rl: | 2023 296 18 13 36 PMT counter failure | 1 | 1 | | | #194 | 05:19:32 | | 1 | -1 |
Instrument constant changes for the week before 2023296 (1 sec, 0 rows)
HG burned out? (AP results when HG is ON) (0 sec, 16 rows)
| Serial | YYYYJJJ | HG Current | HG Voltage |
| 194 | 2023289 | 0.18 | 13.83 |
| 194 | 2023290 | 0.18 | 13.81 |
| 194 | 2023291 | 0.18 | 13.81 |
| 194 | 2023292 | 0.18 | 13.8 |
| 194 | 2023293 | 0.18 | 13.8 |
| 194 | 2023294 | 0.19 | 13.78 |
| 194 | 2023295 | 0.18 | 13.81 |
| 194 | 2023295 | 0.19 | 13.81 |
| 194 | 2023295 | 0.19 | 13.78 |
| 194 | 2023295 | 0.31 | 13.81 |
| 194 | 2023295 | 0.19 | 13.8 |
| 194 | 2023296 | 0.19 | 13.77 |
| 194 | 2023296 | 0.19 | 13.8 |
| 194 | 2023296 | 0.19 | 13.78 |
| 194 | 2023296 | 0.31 | 13.77 |
| 194 | 2023296 | 0.19 | 13.75 |
Non-critical warnings from b-files' comments for days between 2023296 and 2023296 (0 sec, 6 rows)
| Type | Comment | count | priority | fname | location | serial | time | value | min | max |
| rl: | 2023 295 05 22 59 Bad command string. Command string buffer cleared. | 1 | 3 | | | #194 | 05:18:32 | | 1 | -1 |
| rl: | 2023 295 05 22 59 Bad command string. Command string buffer cleared. | 1 | 3 | | | #194 | 05:18:32 | | 1 | -1 |
| rl: | 2023 295 05 22 59 < | 1 | 3 | | | #194 | 05:18:34 | | 1 | -1 |
| rl: | 2023 295 05 38 37 New value set for watermark SUPPLY.VOLTAGE.HIGH[ | 4 | 3 | | | #194 | 05:18:37 | | 1 | -1 |
| ds: | DS intensity too high ( 469012/cy) quitting. | 4 | 99 | | | #194 | 18:13:45 | | 1 | -1 |
| ds: | Suppressed oscillation of filter wheel. | 4 | 5 | | | #194 | 18:21:42 | | 1 | -1 |
Measurements and tests summary.
| _jday | _loc | _serial | _skc | aode | ds | dt | ed | fm | fz | hg | hp | rs | sl | zs |
| 296 | Toronto | #194 | calds,Next schedule will be calds (now calds ZS= 93 ZS= 93.031),Waiting until ZA = | 111 | 113 | 2 | 2 | 27 | 4 | 19 | 17 | 2 | 6 | 17 |
(1 sec)
Dead time (0 sec)
Nothing to report.
Standard lamp R6 (1 sec)
Nothing to report.
Standard lamp R5 (2 sec)
Nothing to report.
Number of days since last dome/window cleaning (0 sec, 2 rows)
| serial | days |
| 194 | more than a year |
Missing files (0 sec, 1 rows)
| Serial | last data | days ago |
| 194 | 2023297 | 0-1 |
Run/Stop results for last week. (0 sec, 1 rows)
| Serial | Total | Failed 0 | Failed dark | Failed 1 | Failed 2 | Failed 3 | Failed 4 | Failed 5 | Failed double |
| 194 | 16 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
AP results for SB Brewers. (0 sec, 1 rows)
| Serial | Jday | t1 off | t1 on | t2 off | t2 on | t3 off | t3 on | HV off | HV on | +12V off | +12V on | +5V off | +5V on | -12V off | -12V on | +24V off | +24V on | +5V sps off | +5V sps on | SL A off | SL A on | SL V off | SL V on | Watts |
| 194 | 2023296 | 19.6 | 19.6 | 20.0 | 20.0 | 19.1 | 19.1 | 1307.3 | 1307.5 | 12.0 | 12.0 | 5.1 | 5.1 | -11.7 | -11.7 | 24.1 | 24.1 | 5.0 | 5.0 | 0.0 | 1.5 | 0.2 | 10.25 | 15.3 |
Standard lamp intensity analysis (0 sec, 1 rows)
| Serial | min | max | filter | fixable | 30-day history |
| #194 | 3140450 | 3140650 | 0 | yes |