Database last updated on Mon, 02 Feb 2026 02:10:51 +0000 by localhost

Critical warnings from b-files' comments for days between 2023172 and 2023172 (0 sec, 2 rows)

TypeCommentcountpriorityfnamelocationserialtimevalueminmax
rl:1992 001 13 01 11 Motor #11: appears stuck with a reference sensor activated.11B17223.194Toron#19405:23:331-1
rl:1992 001 13 06 30 New value set for watermark SUPPLY.VOLTAGE.HIGH[123B17223.194Toron#19405:23:381-1

Instrument constant changes for the week before 2023172 (3 sec, 0 rows)

SL burned out? (AP results when SL is ON) (0 sec, 2 rows)

HG burned out? (AP results when HG is ON) (0 sec, 5 rows)

SerialYYYYJJJHG CurrentHG Voltage
19420231700.1913.67
19420231710.3313.77
19420231710.1813.74
19420231710.3313.75
19420231720.3313.74

HP with step corrections larger than 20 steps (0 sec, 1 rows)

SerialYYYYJJJHP largemax correction
1942023172141.3

Non-critical warnings from b-files' comments for days between 2023172 and 2023172 (0 sec, 7 rows)

TypeCommentcountpriorityfnamelocationserialtimevalueminmax
ds:DS intensity too low ( 2/cy), skipping.299B17223.194Toron#19401:20:101-1
zs:ZS intensity too low ( 31/cy), skipping.299B17223.194Toron#19401:20:251-1
rl:1992 001 13 01 11 Motor #11: appears stuck with a reference sensor activated.13B17223.194Toron#19405:23:331-1
hp:HOME key pressed199B17223.194Toron#19414:29:331-1
pd:Going to menu199B17223.194Toron#19414:29:441-1
si:New SI, HC = 2, NC = 700 Old = 3 , 705199B17223.194Toron#19414:34:311-1
sc:SC intensity too low ( 8/cy), skipping.13B17223.194Toron#19423:15:321-1

Measurements and tests summary.


_jday_loc_serial_skcaodedsedhghpsluvzs
172Toronto#194calsc,Next schedule will be calsc (now calsc ZS= 90 ZS= 91.47899),Next schedule will be calsc (now calsc ZS= 90 ZS= 91.999)2323215132811
(0 sec)

Relative and absolute humidity for day 2023172 (2 sec, 1 rows)

SerialRH, %AH, g/m37-day RH historyDes-nt replcd days ago
1940.90.4