| Type | Comment | count | priority | fname | location | serial | time | value | min | max |
|---|---|---|---|---|---|---|---|---|---|---|
| rl: | 2021 166 05 34 15 New value set for watermark SUPPLY.VOLTAGE.HIGH[-5VSEC]: -4.667063 Volts. | 27 | 3 | B16721.191 | TORON | #191 | 05:27:45 | 1 | -1 | |
| rl: | 2021 167 17 33 59 PMT counter failure | 1 | 1 | B16721.191 | TORON | #191 | 05:28:58 | 1 | -1 |
| Type | Comment | count | priority | fname | location | serial | time | value | min | max |
|---|---|---|---|---|---|---|---|---|---|---|
| rl: | 2021 166 05 33 13 Reset Warm -> Tepid from 2021 166 05 33 08 until 2021 166 05 33 08 . Counts: 1,0 | 1 | 3 | B16721.191 | TORON | #191 | 05:27:43 | 1 | -1 | |
| ds: | DS intensity too high ( 342387/cy) quitting. | 1 | 99 | B16721.191 | TORON | #191 | 22:40:52 | 1 | -1 |
| _jday | _loc | _serial | _skc | aode | ds | dt | ed | fz | hg | hp | rs | sl | uv | zs |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 167 | TORONTO | #191 | ecnouv,Next schedule will be ecnouv (now ecnouv ZS= 93 ZS= 93.033) | 144 | 145 | 2 | 2 | 3 | 22 | 21 | 2 | 7 | 12 | 30 |
| Serial | RH, % | AH, g/m3 | 7-day RH history | Des-nt replcd days ago |
|---|---|---|---|---|
| 191 | 20.5 | 5.4 |