Database last updated on Tue, 15 Sep 2026 10:11:00 +0000 by localhost

Critical warnings from b-files' comments for days between 2018119 and 2018119 (0 sec, 1 rows)

TypeCommentcountpriorityfnamelocationserialtimevalueminmax
rl:2018 118 05 23 04 New value set for watermark SUPPLY.VOLTAGE.HIGH[-5VSEC]: -4.484252 Volts.103B11918.191TORON#19105:19:281-1

Instrument constant changes for the week before 2018119 (3 sec, 0 rows)

SL burned out? (AP results when SL is ON) (0 sec, 3 rows)

HG burned out? (AP results when HG is ON) (0 sec, 9 rows)

Non-critical warnings from b-files' comments for days between 2018119 and 2018119 (0 sec, 2 rows)

TypeCommentcountpriorityfnamelocationserialtimevalueminmax
rl:2018 118 05 22 02 Reset Warm -> Tepid from 2018 118 05 21 57 until 2018 118 05 21 57 . Counts: 1,013B11918.191TORON#19105:19:271-1
zs:ZS is not done when solar zenith angle less than 30 degrees. Skipping.110B11918.191TORON#19116:43:411-1

Measurements and tests summary.


_jday_loc_serial_skcaodedsdtedfmfzhghprsslzs
119TORONTO#191ecnouv1541541130713121826
(1 sec)

New operators? (0 sec, 10 rows)

Relative and absolute humidity for day 2018119 (1 sec, 1 rows)

SerialRH, %AH, g/m37-day RH historyDes-nt replcd days ago
1918.21.3