Database last updated on Tue, 15 Sep 2026 16:41:53 +0000 by localhost
Critical warnings from b-files' comments for days between 2018117 and 2018117 (0 sec, 1 rows)
| Type | Comment | count | priority | fname | location | serial | time | value | min | max |
| rl: | 2018 116 05 27 57 New value set for watermark SUPPLY.VOLTAGE.HIGH[-5VSEC]: -4.650932 Volts. | 27 | 3 | B11718.191 | TORON | #191 | 05:22:19 | | 1 | -1 |
Instrument constant changes for the week before 2018117 (7 sec, 0 rows)
SL burned out? (AP results when SL is ON) (0 sec, 2 rows)
HG burned out? (AP results when HG is ON) (0 sec, 6 rows)
Hg with step corrections larger than 10 steps or multiple corrections larger than 2.5 steps (0 sec, 1 rows)
| Serial | YYYYJJJ | HG large | max correction |
| 191 | 2018117 | 1 | 13.1 |
Non-critical warnings from b-files' comments for days between 2018117 and 2018117 (0 sec, 2 rows)
| Type | Comment | count | priority | fname | location | serial | time | value | min | max |
| rl: | 2018 116 05 26 55 Reset Warm -> Tepid from 2018 116 05 26 49 until 2018 116 05 26 50 . Counts: 1,0 | 1 | 3 | B11718.191 | TORON | #191 | 05:22:17 | | 1 | -1 |
| rl: | 2018 117 08 53 39 New value set for watermark LOOP.RUN.TIME: 659.000015 millisec. | 1 | 3 | B11718.191 | TORON | #191 | 05:22:52 | | 1 | -1 |
Measurements and tests summary.
| _jday | _loc | _serial | _skc | aode | ds | dt | ed | fm | fz | hg | hp | rs | sl | zs |
| 117 | TORONTO | #191 | ecnouv | 148 | 148 | 1 | 1 | 31 | 8 | 20 | 18 | 1 | 6 | 24 |
(0 sec)
New operators? (0 sec, 14 rows)
Relative and absolute humidity for day 2018117 (1 sec, 1 rows)
| Serial | RH, % | AH, g/m3 | 7-day RH history | Des-nt replcd days ago |
| 191 | 8.6 | 2.0 |