Database last updated on Sat, 12 Sep 2026 21:40:57 +0000 by localhost

Critical warnings from b-files' comments for days between 2019077 and 2019077 (0 sec, 1 rows)

TypeCommentcountpriorityfnamelocationserialtimevalueminmax
rl:2019 077 09 58 40 New value set for watermark SUPPLY.VOLTAGE.HIGH[-5VSEC]: -4.699324 Volts.163B07719.190TORON#19005:36:551-1

Instrument constant changes for the week before 2019077 (3 sec, 0 rows)

SL burned out? (AP results when SL is ON) (0 sec, 24 rows)

Non-critical warnings from b-files' comments for days between 2019077 and 2019077 (0 sec, 5 rows)

TypeCommentcountpriorityfnamelocationserialtimevalueminmax
rl:2019 076 05 38 18 Reset Warm -> Tepid from 2019 076 05 38 12 until 2019 076 05 38 13 . Counts: 1,013B07719.190TORON#19005:36:521-1
mf:Illegal command (mf) in schedule ecsc, ignoring399B07719.190TORON#19006:52:531-1
ds:DS intensity too low ( 6/cy), skipping.199B07719.190TORON#19011:39:471-1
zs:ZS intensity too low ( 300/cy), skipping.199B07719.190TORON#19011:40:011-1
ds:Suppressed oscillation of filter wheel.45B07719.190TORON#19013:29:581-1

Measurements and tests summary.


_jday_loc_serial_skcaodedsdtedfmfzhghprssluvzs
077TORONTO#190ecsc5157213421111264914
(0 sec)

Relative and absolute humidity for day 2019077 (2 sec, 1 rows)

SerialRH, %AH, g/m37-day RH historyDes-nt replcd days ago
1901.50.2